{"id":"CVE-2012-2597","aliases":["EUVD-2012-2583","GHSA-rx3w-xv9f-p6wc"],"status":"published","title":"Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow...","description":"Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.","severity":{"version":"2.0","score":4,"vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.02265,"percentile":0.83136,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-22"],"published":"2012-06-08T18:00:00Z","modified":"2026-06-16T23:41:44Z","products":[{"vendor":"siemens","product":"wincc"}],"references":[{"url":"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf","tags":["x_refsource_MISC","x_transferred","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2012-2597"},{"url":"https://github.com/advisories/GHSA-rx3w-xv9f-p6wc"}],"sources":{"cve":[{"id":"CVE-2012-2597","description":"Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.","status":"published","published":"2012-06-08T18:00:00Z","modified":"2024-09-16T17:53:38.472Z","updated_at":"2026-11-02T14:34:50.263482Z"}],"euvd":[{"id":"EUVD-2012-2583","description":"Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.","status":"published","published":"2012-06-08T18:00:00Z","modified":"2024-09-16T17:53:38Z","updated_at":"2026-11-03T00:55:37.743963Z"}],"ghsa":[{"id":"GHSA-rx3w-xv9f-p6wc","title":"Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow...","description":"Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.","status":"published","published":"2022-05-17T05:28:53Z","modified":"2023-01-28T05:04:18Z","cwes":["CWE-22"],"updated_at":"2026-11-02T14:44:08.629318Z"}],"nvd":[{"id":"CVE-2012-2597","description":"Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.","status":"published","published":"2012-06-08T18:55:02.267Z","modified":"2026-06-16T23:41:44.583Z","cvss":[{"version":"2.0","score":4,"vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:02:14.336529Z"}]}}