{"id":"CVE-2013-2824","aliases":["EUVD-2013-2763","GHSA-hcf2-m3fc-44v4"],"status":"published","title":"Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1...","description":"Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.","severity":{"version":"2.0","score":7.8,"vector":"AV:N/AC:L/Au:N/C:N/I:N/A:C","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.01786,"percentile":0.78477,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"published":"2014-02-26T11:00:00Z","modified":"2026-06-16T23:54:01Z","products":[{"vendor":"schneider-electric","product":"citectscada"},{"vendor":"schneider-electric","product":"powerlogic_scada"},{"vendor":"schneider-electric","product":"struxureware_powerscada_expert"},{"vendor":"schneider-electric","product":"struxureware_scada_expert_vijeo_citect"}],"references":[{"url":"http://www.citect.schneider-electric.com/security-DoS","tags":["x_refsource_CONFIRM","x_transferred","Patch","Vendor Advisory"]},{"url":"http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01","tags":["x_refsource_MISC","x_transferred","Patch","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2013-2824"},{"url":"https://github.com/advisories/GHSA-hcf2-m3fc-44v4"}],"sources":{"cve":[{"id":"CVE-2013-2824","description":"Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.","status":"published","published":"2014-02-26T11:00:00Z","modified":"2024-08-06T15:52:20.055Z","updated_at":"2026-11-02T14:34:56.19172Z"}],"euvd":[{"id":"EUVD-2013-2763","description":"Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.","status":"published","published":"2014-02-26T11:00:00Z","modified":"2024-08-06T15:52:20Z","updated_at":"2026-11-03T01:56:37.731533Z"}],"ghsa":[{"id":"GHSA-hcf2-m3fc-44v4","title":"Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1...","description":"Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.","status":"published","published":"2022-05-17T04:51:39Z","modified":"2023-01-28T05:02:39Z","updated_at":"2026-11-02T14:43:49.260703Z"}],"nvd":[{"id":"CVE-2013-2824","description":"Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.","status":"published","published":"2014-02-26T14:55:08.147Z","modified":"2026-06-16T23:54:01.45Z","cvss":[{"version":"2.0","score":7.8,"vector":"AV:N/AC:L/Au:N/C:N/I:N/A:C","level":"high","assessor":"primary"}],"updated_at":"2026-11-02T14:02:48.062712Z"}]}}