{"id":"CVE-2015-4174","aliases":["EUVD-2015-4197","GHSA-4239-64c9-rvg2"],"status":"published","title":"Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix...","description":"Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.","severity":{"version":"2.0","score":4.3,"vector":"AV:N/AC:M/Au:N/C:N/I:P/A:N","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.02526,"percentile":0.84988,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-79"],"published":"2015-06-28T10:00:00Z","modified":"2026-06-17T00:26:51Z","products":[{"vendor":"siemens","product":"climatix_bacnet\\/ip"}],"references":[{"url":"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-142512.pdf","tags":["x_refsource_CONFIRM","x_transferred","Patch","Vendor Advisory"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-176-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"http://www.securityfocus.com/bid/75427","tags":["vdb-entry","x_refsource_BID","x_transferred"]},{"url":"http://packetstormsecurity.com/files/132514/Climatix-BACnet-IP-Communication-Module-Cross-Site-Scripting.html","tags":["x_refsource_MISC","x_transferred","Exploit"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2015-4174"},{"url":"https://github.com/advisories/GHSA-4239-64c9-rvg2"}],"sources":{"cve":[{"id":"CVE-2015-4174","description":"Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.","status":"published","published":"2015-06-28T10:00:00Z","modified":"2024-08-06T06:04:02.909Z","updated_at":"2026-11-02T14:35:43.322279Z"}],"euvd":[{"id":"EUVD-2015-4197","description":"Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.","status":"published","published":"2015-06-28T10:00:00Z","modified":"2024-08-06T06:04:02Z","updated_at":"2026-11-03T02:22:05.081899Z"}],"ghsa":[{"id":"GHSA-4239-64c9-rvg2","title":"Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix...","description":"Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.","status":"published","published":"2022-05-17T03:28:13Z","modified":"2023-01-27T05:07:03Z","cwes":["CWE-79"],"updated_at":"2026-11-02T14:43:02.793588Z"}],"nvd":[{"id":"CVE-2015-4174","description":"Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.","status":"published","published":"2015-06-28T10:59:02.363Z","modified":"2026-06-17T00:26:51.923Z","cvss":[{"version":"2.0","score":4.3,"vector":"AV:N/AC:M/Au:N/C:N/I:P/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:03:05.884985Z"}]}}