{"id":"CVE-2015-6462","aliases":["EUVD-2015-6403","GHSA-3gx4-563f-8wxf"],"status":"published","title":"Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which...","description":"Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.","severity":{"version":"3.0","score":5.4,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-07","score":0.0056,"percentile":0.46849,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-79"],"published":"2019-03-21T18:44:47Z","modified":"2026-06-17T00:30:54Z","products":[{"vendor":"schneider-electric","product":"bmxnoc0401_firmware"},{"vendor":"schneider-electric","product":"bmxnoe0100_firmware"},{"vendor":"schneider-electric","product":"bmxnoe0110_firmware"},{"vendor":"schneider-electric","product":"bmxnoe0110h_firmware"},{"vendor":"schneider-electric","product":"bmxnor0200h_firmware"},{"vendor":"schneider-electric","product":"modicon_m340_bmxp342020_firmware"},{"vendor":"schneider-electric","product":"modicon_m340_bmxp342020h_firmware"},{"vendor":"schneider-electric","product":"modicon_m340_bmxp3420302_firmware"},{"vendor":"schneider-electric","product":"modicon_m340_bmxp3420302h_firmware"},{"vendor":"schneider-electric","product":"modicon_m340_bmxp342030_firmware"},{"vendor":"schneider-electric","product":"modicon_m340_bmxp342030h_firmware"}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2015-6462"},{"url":"https://github.com/advisories/GHSA-3gx4-563f-8wxf"}],"sources":{"cve":[{"id":"CVE-2015-6462","description":"Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.","status":"published","published":"2019-03-21T18:44:47Z","modified":"2024-08-06T07:22:21.488Z","cwes":["CWE-79"],"updated_at":"2026-11-02T14:35:42.680858Z"}],"euvd":[{"id":"EUVD-2015-6403","description":"Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.","status":"published","published":"2019-03-21T18:44:47Z","modified":"2024-08-06T07:22:21Z","updated_at":"2026-11-03T02:21:55.706543Z"}],"ghsa":[{"id":"GHSA-3gx4-563f-8wxf","title":"Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which...","description":"Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.","status":"published","published":"2022-05-13T01:38:53Z","modified":"2023-02-01T05:09:20Z","cvss":[{"version":"3.0","score":5.4,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","level":"medium"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:50:56.168791Z"}],"nvd":[{"id":"CVE-2015-6462","description":"Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.","status":"published","published":"2019-03-21T19:29:00.317Z","modified":"2026-06-17T00:30:54.6Z","cvss":[{"version":"3.0","score":5.4,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"primary"},{"version":"2.0","score":3.5,"vector":"AV:N/AC:M/Au:S/C:N/I:P/A:N","level":"low","assessor":"primary"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:03:19.73542Z"}]}}