{"id":"CVE-2016-4513","aliases":["EUVD-2016-5500","GHSA-g2cq-whvf-jv55"],"status":"published","title":"Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module...","description":"Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.","severity":{"version":"3.0","score":6.1,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.00906,"percentile":0.60103,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-79"],"published":"2016-06-26T01:00:00Z","modified":"2026-06-17T00:47:41Z","products":[{"vendor":"schneider-electric","product":"powerlogic_pm8ecc_firmware"}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-173-02","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2016-4513"},{"url":"https://github.com/advisories/GHSA-g2cq-whvf-jv55"}],"sources":{"cve":[{"id":"CVE-2016-4513","description":"Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.","status":"published","published":"2016-06-26T01:00:00Z","modified":"2024-08-06T00:32:25.679Z","updated_at":"2026-11-02T14:33:35.149563Z"}],"euvd":[{"id":"EUVD-2016-5500","description":"Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.","status":"published","published":"2016-06-26T01:00:00Z","modified":"2024-08-06T00:32:25Z","updated_at":"2026-11-03T02:22:46.329763Z"}],"ghsa":[{"id":"GHSA-g2cq-whvf-jv55","title":"Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module...","description":"Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.","status":"published","published":"2022-05-17T03:52:21Z","modified":"2023-01-28T05:00:38Z","cvss":[{"version":"3.0","score":6.1,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:43:23.362712Z"}],"nvd":[{"id":"CVE-2016-4513","description":"Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.","status":"published","published":"2016-06-26T01:59:03.647Z","modified":"2026-06-17T00:47:41.93Z","cvss":[{"version":"3.0","score":6.1,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"primary"},{"version":"2.0","score":4.3,"vector":"AV:N/AC:M/Au:N/C:N/I:P/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:03:26.642445Z"}]}}