{"id":"CVE-2017-12707","aliases":["EUVD-2017-4246","GHSA-8wgf-xcfp-h3mg"],"status":"published","title":"A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1...","description":"A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1.6.30.144 and prior. Opening a maliciously crafted html file may cause a stack overflow.","severity":{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-07","score":0.02612,"percentile":0.85513,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-119","CWE-121"],"published":"2017-08-25T19:00:00Z","modified":"2026-06-17T01:03:49Z","products":[{"vendor":"spidercontrol","product":"scada_microbrowser"}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-234-02","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"http://www.securityfocus.com/bid/100453","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-12707"},{"url":"https://github.com/advisories/GHSA-8wgf-xcfp-h3mg"}],"sources":{"cve":[{"id":"CVE-2017-12707","description":"A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1.6.30.144 and prior. Opening a maliciously crafted html file may cause a stack overflow.","status":"published","published":"2017-08-25T19:00:00Z","modified":"2024-08-05T18:43:56.479Z","cwes":["CWE-121"],"updated_at":"2026-11-02T14:33:17.264801Z"}],"euvd":[{"id":"EUVD-2017-4246","description":"A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1.6.30.144 and prior. Opening a maliciously crafted html file may cause a stack overflow.","status":"published","published":"2017-08-25T19:00:00Z","modified":"2024-08-05T18:43:56Z","updated_at":"2026-11-03T02:23:20.716903Z"}],"ghsa":[{"id":"GHSA-8wgf-xcfp-h3mg","title":"A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1...","description":"A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1.6.30.144 and prior. Opening a maliciously crafted html file may cause a stack overflow.","status":"published","published":"2022-05-13T01:37:46Z","modified":"2025-04-20T03:44:54Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-119","CWE-121"],"updated_at":"2026-11-02T15:01:51.143792Z"}],"nvd":[{"id":"CVE-2017-12707","description":"A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1.6.30.144 and prior. Opening a maliciously crafted html file may cause a stack overflow.","status":"published","published":"2017-08-25T19:29:00.237Z","modified":"2026-06-17T01:03:49.193Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","level":"high","assessor":"primary"}],"cwes":["CWE-121","CWE-119"],"updated_at":"2026-11-02T14:03:57.82609Z"}]}}