{"id":"CVE-2017-14006","aliases":["EUVD-2017-5521","GHSA-ghg8-72p6-f85w"],"status":"published","title":"GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are...","description":"GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.","severity":{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-07","score":0.01861,"percentile":0.79371,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-287","CWE-798"],"published":"2018-03-20T16:00:00Z","modified":"2026-06-17T01:05:25Z","products":[{"vendor":"ge","product":"xeleris"},{"vendor":"ge healthcare","product":"ge xeleris"}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02","tags":["x_refsource_MISC","x_transferred","Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-14006"},{"url":"https://github.com/advisories/GHSA-ghg8-72p6-f85w"}],"sources":{"cve":[{"id":"CVE-2017-14006","description":"GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.","status":"published","published":"2018-03-20T16:00:00Z","modified":"2024-09-16T23:20:54.531Z","cwes":["CWE-287"],"updated_at":"2026-11-02T14:33:12.267141Z"}],"euvd":[{"id":"EUVD-2017-5521","description":"GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.","status":"published","published":"2018-03-20T16:00:00Z","modified":"2024-09-16T23:20:54Z","updated_at":"2026-11-03T00:54:54.692655Z"}],"ghsa":[{"id":"GHSA-ghg8-72p6-f85w","title":"GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are...","description":"GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.","status":"published","published":"2022-05-13T01:37:40Z","modified":"2023-02-01T05:08:46Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:50:51.059157Z"}],"nvd":[{"id":"CVE-2017-14006","description":"GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.","status":"published","published":"2018-03-20T16:29:00.373Z","modified":"2026-06-17T01:05:25.81Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","level":"high","assessor":"primary"}],"cwes":["CWE-287","CWE-798"],"updated_at":"2026-11-02T14:04:17.032862Z"}]}}