{"id":"CVE-2017-14020","aliases":["EUVD-2017-5535","GHSA-c97g-x65q-5xr4"],"status":"published","title":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C...","description":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.","severity":{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.01135,"percentile":0.66732,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-427"],"published":"2017-11-13T20:00:00Z","modified":"2026-06-17T01:05:27Z","products":[{"vendor":"automationdirect","product":"c-more micro (part number ea-pgmsw)"},{"vendor":"automationdirect","product":"c-more programming software (part number ea9-pgmsw)"},{"vendor":"automationdirect","product":"c-more_micro_firmware"},{"vendor":"automationdirect","product":"c-more_plc_firmware"},{"vendor":"automationdirect","product":"click programming software (part number c0-pgmsw)"},{"vendor":"automationdirect","product":"click_plc_firmware"},{"vendor":"automationdirect","product":"directsoft programming software"},{"vendor":"automationdirect","product":"do-more designer software (part number dm-pgmsw)"},{"vendor":"automationdirect","product":"gs drives configuration software (part number gsoft)"},{"vendor":"automationdirect","product":"gs_drives_fimware"},{"vendor":"automationdirect","product":"sl-soft solo temperature controller configuration software (part number sl-soft)"},{"vendor":"automationdirect","product":"sl-soft_solo_temperature_controller_firmware"}],"references":[{"url":"http://www.securityfocus.com/bid/101780","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-01","tags":["x_refsource_MISC","x_transferred","Issue Tracking","Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-14020"},{"url":"https://github.com/advisories/GHSA-c97g-x65q-5xr4"}],"sources":{"cve":[{"id":"CVE-2017-14020","description":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.","status":"published","published":"2017-11-13T20:00:00Z","modified":"2024-09-17T02:16:03.522Z","cwes":["CWE-427"],"updated_at":"2026-11-02T14:33:12.267141Z"}],"euvd":[{"id":"EUVD-2017-5535","description":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.","status":"published","published":"2017-11-13T20:00:00Z","modified":"2024-09-17T02:16:03Z","updated_at":"2026-11-03T00:28:42.412483Z"}],"ghsa":[{"id":"GHSA-c97g-x65q-5xr4","title":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C...","description":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.","status":"published","published":"2022-05-14T03:11:43Z","modified":"2023-02-02T05:07:06Z","cvss":[{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-427"],"updated_at":"2026-11-02T14:52:25.892644Z"}],"nvd":[{"id":"CVE-2017-14020","description":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.","status":"published","published":"2017-11-13T20:29:00.257Z","modified":"2026-06-17T01:05:27.193Z","cvss":[{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":9.3,"vector":"AV:N/AC:M/Au:N/C:C/I:C/A:C","level":"high","assessor":"primary"}],"cwes":["CWE-427"],"updated_at":"2026-11-02T14:04:08.635428Z"}]}}