{"id":"CVE-2017-20214","aliases":["EUVD-2026-1609","GHSA-mgmw-cpxg-gc2f"],"status":"published","title":"FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 Hard-Coded SSH Credentials Vulnerability","description":"FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.","severity":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.00329,"percentile":0.26245,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-798"],"published":"2026-01-07T23:09:55Z","modified":"2026-06-17T01:15:25Z","products":[{"vendor":"flir systems, inc.","product":"flir thermal camera f/fc/pt/d"}],"references":[{"url":"https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5436.php","tags":["third-party-advisory","exploit"]},{"url":"https://www.exploit-db.com/exploits/42787/","tags":["exploit"]},{"url":"https://packetstormsecurity.com/files/144324","tags":["exploit"]},{"url":"https://cxsecurity.com/issue/WLB-2017090205","tags":["third-party-advisory"]},{"url":"https://web.archive.org/web/20171011125811/https://www.flir.com/security/blog/details/?ID=87043","tags":["vendor-advisory","patch"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-20214"},{"url":"https://www.exploit-db.com/exploits/42787"},{"url":"https://github.com/advisories/GHSA-mgmw-cpxg-gc2f"}],"sources":{"cve":[{"id":"CVE-2017-20214","title":"FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 Hard-Coded SSH Credentials Vulnerability","description":"FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.","status":"published","published":"2026-01-07T23:09:55.85Z","modified":"2026-04-07T14:03:39.377Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical","assessor":"cna"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"cna"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:33:11.59359Z"}],"euvd":[{"id":"EUVD-2026-1609","description":"FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.","status":"published","published":"2026-01-07T23:09:55Z","modified":"2026-04-07T14:03:39Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical"}],"updated_at":"2026-11-02T19:25:14.189276Z"}],"ghsa":[{"id":"GHSA-mgmw-cpxg-gc2f","title":"FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that...","description":"FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.","status":"published","published":"2026-01-08T00:31:14Z","modified":"2026-01-08T00:31:21Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high"},{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"critical"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T15:05:32.392087Z"}],"nvd":[{"id":"CVE-2017-20214","description":"FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.","status":"published","published":"2026-01-08T00:15:56.513Z","modified":"2026-06-17T01:15:25.643Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"critical","assessor":"secondary"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"secondary"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:04:21.76411Z"}]}}