{"id":"CVE-2017-9941","aliases":["EUVD-2017-18851","GHSA-whwx-j639-prvw"],"status":"published","title":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that...","description":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.","severity":{"version":"3.0","score":7.4,"vector":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.00948,"percentile":0.61414,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-300"],"published":"2017-08-08T00:00:00Z","modified":"2026-06-17T01:29:15Z","products":[{"vendor":"siemens","product":"sipass_integrated"}],"references":[{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/99578","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-9941"},{"url":"https://github.com/advisories/GHSA-whwx-j639-prvw"}],"sources":{"cve":[{"id":"CVE-2017-9941","description":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.","status":"published","published":"2017-08-08T00:00:00Z","modified":"2024-08-05T17:25:00.468Z","cwes":["CWE-300"],"updated_at":"2026-11-02T14:33:13.96587Z"}],"euvd":[{"id":"EUVD-2017-18851","description":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.","status":"published","published":"2017-08-08T00:00:00Z","modified":"2024-08-05T17:25:00Z","updated_at":"2026-11-03T02:23:26.143318Z"}],"ghsa":[{"id":"GHSA-whwx-j639-prvw","title":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that...","description":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.","status":"published","published":"2022-05-13T01:36:04Z","modified":"2025-04-20T03:42:24Z","cvss":[{"version":"3.0","score":7.4,"vector":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","level":"high"}],"cwes":["CWE-300"],"updated_at":"2026-11-02T15:01:49.538564Z"}],"nvd":[{"id":"CVE-2017-9941","description":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.","status":"published","published":"2017-08-08T00:29:00.447Z","modified":"2026-06-17T01:29:15.26Z","cvss":[{"version":"3.0","score":7.4,"vector":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","level":"high","assessor":"primary"},{"version":"2.0","score":5.8,"vector":"AV:N/AC:M/Au:N/C:P/I:P/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-300"],"updated_at":"2026-11-02T14:03:57.282351Z"}]}}