{"id":"CVE-2018-1168","aliases":["EUVD-2018-11806","GHSA-fcm3-cc23-mg3g"],"status":"published","title":"This vulnerability allows local attackers to escalate privileges on vulnerable installations of...","description":"This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.","severity":{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.00312,"percentile":0.24313,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-284","CWE-732"],"published":"2018-02-21T14:00:00Z","modified":"2026-06-17T01:50:37Z","products":[{"vendor":"abb","product":"abb microscada"},{"vendor":"hitachienergy","product":"sys600_firmware"}],"references":[{"url":"https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC","tags":["x_refsource_CONFIRM","x_transferred","Mitigation","Vendor Advisory"]},{"url":"https://zerodayinitiative.com/advisories/ZDI-18-141","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-1168"},{"url":"https://github.com/advisories/GHSA-fcm3-cc23-mg3g"}],"sources":{"cve":[{"id":"CVE-2018-1168","description":"This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.","status":"published","published":"2018-02-21T14:00:00Z","modified":"2024-08-05T03:51:48.99Z","cwes":["CWE-284"],"updated_at":"2026-11-02T14:35:08.701206Z"}],"euvd":[{"id":"EUVD-2018-11806","description":"This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.","status":"published","published":"2018-02-21T14:00:00Z","modified":"2024-08-05T03:51:48Z","updated_at":"2026-11-03T02:40:16.874515Z"}],"ghsa":[{"id":"GHSA-fcm3-cc23-mg3g","title":"This vulnerability allows local attackers to escalate privileges on vulnerable installations of...","description":"This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.","status":"published","published":"2022-05-13T01:33:27Z","modified":"2023-04-19T18:30:50Z","cvss":[{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-284","CWE-732"],"updated_at":"2026-11-02T14:54:31.754243Z"}],"nvd":[{"id":"CVE-2018-1168","description":"This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.","status":"published","published":"2018-02-21T14:29:00.58Z","modified":"2026-06-17T01:50:37.76Z","cvss":[{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":7.2,"vector":"AV:L/AC:L/Au:N/C:C/I:C/A:C","level":"high","assessor":"primary"}],"cwes":["CWE-284","CWE-732"],"updated_at":"2026-11-02T14:04:23.783914Z"}]}}