{"id":"CVE-2018-17064","aliases":["EUVD-2018-8845","GHSA-84r6-xg2x-5pxw"],"status":"published","title":"An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used...","description":"An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command injection via the syslogIp parameter after /goform/clearlog is invoked.","severity":{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.07381,"percentile":0.94461,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-78"],"published":"2018-09-15T21:00:00Z","modified":"2026-06-17T01:45:18Z","products":[{"vendor":"dlink","product":"dir-816_a2_firmware"}],"references":[{"url":"https://github.com/PAGalaxyLab/VulInfo/tree/master/D-Link/DIR-816/cmd_injection_2","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-17064"},{"url":"https://github.com/advisories/GHSA-84r6-xg2x-5pxw"}],"sources":{"cve":[{"id":"CVE-2018-17064","description":"An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command injection via the syslogIp parameter after /goform/clearlog is invoked.","status":"published","published":"2018-09-15T21:00:00Z","modified":"2024-08-05T10:39:59.552Z","updated_at":"2026-11-02T14:35:07.672841Z"}],"euvd":[{"id":"EUVD-2018-8845","description":"An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command injection via the syslogIp parameter after /goform/clearlog is invoked.","status":"published","published":"2018-09-15T21:00:00Z","modified":"2024-08-05T10:39:59Z","updated_at":"2026-11-03T02:39:39.763591Z"}],"ghsa":[{"id":"GHSA-84r6-xg2x-5pxw","title":"An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used...","description":"An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command injection via the syslogIp parameter after /goform/clearlog is invoked.","status":"published","published":"2022-05-13T01:50:30Z","modified":"2023-02-02T05:01:52Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:51:17.485612Z"}],"nvd":[{"id":"CVE-2018-17064","description":"An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command injection via the syslogIp parameter after /goform/clearlog is invoked.","status":"published","published":"2018-09-15T21:29:00.41Z","modified":"2026-06-17T01:45:18.233Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":10,"vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","level":"high","assessor":"primary"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:04:40.661264Z"}]}}