{"id":"CVE-2018-7813","aliases":["EUVD-2018-19525","GHSA-wg5j-5hmx-g6c3"],"status":"published","title":"A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 ...","description":"A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on pcwin.dll which could cause remote code to be executed when parsing a GD1 file","severity":{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-10","score":0.0114,"percentile":0.66889,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-704"],"published":"2019-02-06T23:00:00Z","modified":"2026-06-17T02:03:46Z","products":[{"vendor":"schneider electric se","product":"eurotherm by schneider electric guicon v2.0 (gold build 683.0)"},{"vendor":"schneider-electric","product":"guicon"}],"references":[{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2018-338-01","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/106218","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-7813"},{"url":"https://github.com/advisories/GHSA-wg5j-5hmx-g6c3"}],"sources":{"cve":[{"id":"CVE-2018-7813","description":"A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on pcwin.dll which could cause remote code to be executed when parsing a GD1 file","status":"published","published":"2019-02-06T23:00:00Z","modified":"2024-08-05T06:37:59.24Z","updated_at":"2026-11-02T14:35:09.908186Z"}],"euvd":[{"id":"EUVD-2018-19525","description":"A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on pcwin.dll which could cause remote code to be executed when parsing a GD1 file","status":"published","published":"2019-02-06T23:00:00Z","modified":"2024-08-05T06:37:59Z","updated_at":"2026-11-03T02:40:04.680788Z"}],"ghsa":[{"id":"GHSA-wg5j-5hmx-g6c3","title":"A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 ...","description":"A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on pcwin.dll which could cause remote code to be executed when parsing a GD1 file","status":"published","published":"2022-05-14T01:35:48Z","modified":"2023-02-02T05:04:07Z","cvss":[{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-704"],"updated_at":"2026-11-02T14:51:47.403205Z"}],"nvd":[{"id":"CVE-2018-7813","description":"A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on pcwin.dll which could cause remote code to be executed when parsing a GD1 file","status":"published","published":"2019-02-06T23:29:00.48Z","modified":"2026-06-17T02:03:46.943Z","cvss":[{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":6.8,"vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-704"],"updated_at":"2026-11-02T14:04:53.728218Z"}]}}
