{"id":"CVE-2018-7840","aliases":["EUVD-2018-19552","GHSA-f6jf-8jc8-q659"],"status":"published","title":"A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter...","description":"A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL.","severity":{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-07","score":0.00943,"percentile":0.61243,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-427"],"published":"2019-05-22T19:24:55Z","modified":"2026-06-17T02:03:50Z","products":[{"vendor":"pelco","product":"videoxpert_opscenter"},{"vendor":"videoxpert","product":"videoxpert opscenter versions prior to 3.1"}],"references":[{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-7840"},{"url":"https://github.com/advisories/GHSA-f6jf-8jc8-q659"}],"sources":{"cve":[{"id":"CVE-2018-7840","description":"A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL.","status":"published","published":"2019-05-22T19:24:55Z","modified":"2024-08-05T06:37:59.645Z","updated_at":"2026-11-02T14:35:10.313768Z"}],"euvd":[{"id":"EUVD-2018-19552","description":"A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL.","status":"published","published":"2019-05-22T19:24:55Z","modified":"2024-08-05T06:37:59Z","updated_at":"2026-11-03T02:40:04.680788Z"}],"ghsa":[{"id":"GHSA-f6jf-8jc8-q659","title":"A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter...","description":"A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL.","status":"published","published":"2022-05-24T16:46:12Z","modified":"2024-04-04T00:43:33Z","cvss":[{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-427"],"updated_at":"2026-11-02T14:55:51.66271Z"}],"nvd":[{"id":"CVE-2018-7840","description":"A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL.","status":"published","published":"2019-05-22T20:29:01.433Z","modified":"2026-06-17T02:03:50.393Z","cvss":[{"version":"3.0","score":7.8,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":6.8,"vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-427"],"updated_at":"2026-11-02T14:04:57.307075Z"}]}}