{"id":"CVE-2018-8846","aliases":["EUVD-2018-20454","GHSA-c9hq-6wqx-rf95"],"status":"published","title":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not...","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.","severity":{"version":"3.0","score":6.1,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.01259,"percentile":0.69777,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-79"],"published":"2018-09-26T19:00:00Z","modified":"2026-06-17T02:05:30Z","products":[{"vendor":"philips","product":"e-alert unit (non-medical device)"},{"vendor":"philips","product":"e-alert_firmware"}],"references":[{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/105194","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01","tags":["x_refsource_MISC","x_transferred","Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-8846"},{"url":"https://github.com/advisories/GHSA-c9hq-6wqx-rf95"}],"sources":{"cve":[{"id":"CVE-2018-8846","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.","status":"published","published":"2018-09-26T19:00:00Z","modified":"2024-09-16T21:56:29.045Z","cwes":["CWE-79"],"updated_at":"2026-11-02T14:35:04.172099Z"}],"euvd":[{"id":"EUVD-2018-20454","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.","status":"published","published":"2018-09-26T19:00:00Z","modified":"2024-09-16T21:56:29Z","updated_at":"2026-11-03T00:55:07.646084Z"}],"ghsa":[{"id":"GHSA-c9hq-6wqx-rf95","title":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not...","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.","status":"published","published":"2022-05-13T01:31:49Z","modified":"2023-02-01T05:08:24Z","cvss":[{"version":"3.0","score":6.1,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:50:45.067904Z"}],"nvd":[{"id":"CVE-2018-8846","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.","status":"published","published":"2018-09-26T19:29:01.363Z","modified":"2026-06-17T02:05:30.037Z","cvss":[{"version":"3.0","score":6.1,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"primary"},{"version":"2.0","score":4.3,"vector":"AV:N/AC:M/Au:N/C:N/I:P/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:04:42.52179Z"}]}}
