{"id":"CVE-2018-8856","aliases":["EUVD-2018-20464","GHSA-rr4p-hprw-ppwf"],"status":"published","title":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard...","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.","severity":{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.01378,"percentile":0.72264,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-798"],"published":"2018-09-26T19:00:00Z","modified":"2026-06-17T02:05:31Z","products":[{"vendor":"philips","product":"e-alert unit (non-medical device)"},{"vendor":"philips","product":"e-alert_firmware"}],"references":[{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/105194","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01","tags":["x_refsource_MISC","x_transferred","Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-8856"},{"url":"https://github.com/advisories/GHSA-rr4p-hprw-ppwf"}],"sources":{"cve":[{"id":"CVE-2018-8856","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.","status":"published","published":"2018-09-26T19:00:00Z","modified":"2024-09-17T01:56:15.854Z","updated_at":"2026-11-02T14:35:04.172099Z"}],"euvd":[{"id":"EUVD-2018-20464","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.","status":"published","published":"2018-09-26T19:00:00Z","modified":"2024-09-17T01:56:15Z","updated_at":"2026-11-03T00:28:45.29969Z"}],"ghsa":[{"id":"GHSA-rr4p-hprw-ppwf","title":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard...","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.","status":"published","published":"2022-05-14T01:57:32Z","modified":"2023-02-02T05:04:52Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:51:58.811434Z"}],"nvd":[{"id":"CVE-2018-8856","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.","status":"published","published":"2018-09-26T19:29:03.347Z","modified":"2026-06-17T02:05:31.447Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:04:42.52179Z"}]}}