{"id":"CVE-2019-10930","aliases":["EUVD-2019-2644","GHSA-47fm-3fq2-mf5q"],"status":"published","title":"A vulnerability has been identified in SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87,...","description":"A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system.","severity":{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.01763,"percentile":0.78199,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-434","CWE-552"],"published":"2019-07-11T21:17:47Z","modified":"2026-06-17T02:11:55Z","products":[{"vendor":"siemens","product":"digsi_5_engineering_software"},{"vendor":"siemens","product":"siprotec_5_digsi_device_driver"},{"vendor":"siemens ag","product":"all other siprotec 5 device types with cpu variants cp300 and cp100 and the respective ethernet communication modules"},{"vendor":"siemens ag","product":"digsi 5 engineering software"},{"vendor":"siemens ag","product":"siprotec 5 device types 6md85, 6md86, 6md89, 7um85, 7sa87, 7sd87, 7sl87, 7vk87, 7sa82, 7sa86, 7sd82, 7sd86, 7sl82, 7sl86, 7sj86, 7sk82, 7sk85, 7sj82, 7sj85, 7ut82, 7ut85, 7ut86, 7ut87 and 7ve85 with cpu variants cp300 and cp100 and the respective ethernet communication modules"},{"vendor":"siemens ag","product":"siprotec 5 device types 7ss85 and 7ke85"},{"vendor":"siemens ag","product":"siprotec 5 device types with cpu variants cp200 and the respective ethernet communication modules"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-10930"},{"url":"https://github.com/advisories/GHSA-47fm-3fq2-mf5q"}],"sources":{"cve":[{"id":"CVE-2019-10930","description":"A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system.","status":"published","published":"2019-07-11T21:17:47Z","modified":"2024-08-04T22:40:15.221Z","cwes":["CWE-552"],"updated_at":"2026-11-02T14:20:19.399352Z"}],"euvd":[{"id":"EUVD-2019-2644","description":"A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system.","status":"published","published":"2019-07-11T21:17:47Z","modified":"2024-08-04T22:40:15Z","updated_at":"2026-11-03T02:40:50.763878Z"}],"ghsa":[{"id":"GHSA-47fm-3fq2-mf5q","title":"A vulnerability has been identified in SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87,...","description":"A vulnerability has been identified in SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions), DIGSI 5 engineering software (All versions \u003c V7.90). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system.","status":"published","published":"2022-05-24T16:50:11Z","modified":"2023-01-28T05:06:05Z","updated_at":"2026-11-02T14:44:24.376453Z"}],"nvd":[{"id":"CVE-2019-10930","description":"A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system.","status":"published","published":"2019-07-11T22:15:11.56Z","modified":"2026-06-17T02:11:55.953Z","cvss":[{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","level":"high","assessor":"primary"},{"version":"2.0","score":6.4,"vector":"AV:N/AC:L/Au:N/C:N/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-552","CWE-434"],"updated_at":"2026-11-02T14:05:19.195714Z"}]}}