{"id":"CVE-2019-10935","aliases":["EUVD-2019-2649","GHSA-3hg6-vvm5-64f6"],"status":"published","title":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS...","description":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.","severity":{"version":"3.0","score":7.2,"vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.01274,"percentile":0.70081,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-434"],"published":"2019-07-11T21:17:47Z","modified":"2026-06-17T02:11:56Z","products":[{"vendor":"siemens","product":"simatic pcs 7 v8.0 and earlier"},{"vendor":"siemens","product":"simatic pcs 7 v8.1"},{"vendor":"siemens","product":"simatic pcs 7 v8.2"},{"vendor":"siemens","product":"simatic pcs 7 v9.0"},{"vendor":"siemens","product":"simatic wincc professional (tia portal v13)"},{"vendor":"siemens","product":"simatic wincc professional (tia portal v14)"},{"vendor":"siemens","product":"simatic wincc professional (tia portal v15)"},{"vendor":"siemens","product":"simatic wincc runtime professional v13"},{"vendor":"siemens","product":"simatic wincc runtime professional v14"},{"vendor":"siemens","product":"simatic wincc runtime professional v15"},{"vendor":"siemens","product":"simatic wincc v7.2 and earlier"},{"vendor":"siemens","product":"simatic wincc v7.3"},{"vendor":"siemens","product":"simatic wincc v7.4"},{"vendor":"siemens","product":"simatic wincc v7.5"},{"vendor":"siemens","product":"simatic_pcs_7"},{"vendor":"siemens","product":"simatic_wincc"},{"vendor":"siemens","product":"simatic_wincc_runtime"},{"vendor":"siemens ag","product":"simatic pcs 7 v8.0 and earlier"},{"vendor":"siemens ag","product":"simatic pcs 7 v8.1"},{"vendor":"siemens ag","product":"simatic pcs 7 v8.2"},{"vendor":"siemens ag","product":"simatic pcs 7 v9.0"},{"vendor":"siemens ag","product":"simatic wincc professional (tia portal v13)"},{"vendor":"siemens ag","product":"simatic wincc professional (tia portal v14)"},{"vendor":"siemens ag","product":"simatic wincc professional (tia portal v15)"},{"vendor":"siemens ag","product":"simatic wincc runtime professional v13"},{"vendor":"siemens ag","product":"simatic wincc runtime professional v14"},{"vendor":"siemens ag","product":"simatic wincc runtime professional v15"},{"vendor":"siemens ag","product":"simatic wincc v7.2 and earlier"},{"vendor":"siemens ag","product":"simatic wincc v7.3"},{"vendor":"siemens ag","product":"simatic wincc v7.4"},{"vendor":"siemens ag","product":"simatic wincc v7.5"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf","tags":["x_refsource_CONFIRM","x_transferred","Patch","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-10935"},{"url":"http://www.securityfocus.com/bid/109127"},{"url":"https://github.com/advisories/GHSA-3hg6-vvm5-64f6"}],"sources":{"cve":[{"id":"CVE-2019-10935","description":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.","status":"published","published":"2019-07-11T21:17:47Z","modified":"2024-08-04T22:40:15.303Z","cwes":["CWE-434"],"updated_at":"2026-11-02T14:20:19.399352Z"}],"euvd":[{"id":"EUVD-2019-2649","description":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.","status":"published","published":"2019-07-11T21:17:47Z","modified":"2024-08-04T22:40:15Z","updated_at":"2026-11-03T02:40:50.763878Z"}],"ghsa":[{"id":"GHSA-3hg6-vvm5-64f6","title":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS...","description":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions), SIMATIC WinCC Professional (TIA Portal V15) (All versions), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions), SIMATIC WinCC Runtime Professional V15 (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.","status":"published","published":"2022-05-24T16:50:11Z","modified":"2024-04-04T01:15:24Z","cvss":[{"version":"3.0","score":7.2,"vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-434"],"updated_at":"2026-11-02T14:55:56.730661Z"}],"nvd":[{"id":"CVE-2019-10935","description":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.","status":"published","published":"2019-07-11T22:15:11.797Z","modified":"2026-06-17T02:11:56.493Z","cvss":[{"version":"3.0","score":7.2,"vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":6.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-434"],"updated_at":"2026-11-02T14:05:19.195714Z"}]}}