{"id":"CVE-2019-10994","aliases":["EUVD-2019-2708","GHSA-p462-h7q3-m5gx"],"status":"published","title":"Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds...","description":"Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).","severity":{"version":"3.0","score":3.3,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","level":"low","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.00857,"percentile":0.58671,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-125"],"published":"2019-08-05T18:41:18Z","modified":"2026-06-17T02:12:04Z","products":[{"vendor":"laquisscada","product":"scada"},{"vendor":"lcds","product":"lcds laquis scada"}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-19-213-06","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-10994"},{"url":"https://github.com/advisories/GHSA-p462-h7q3-m5gx"}],"sources":{"cve":[{"id":"CVE-2019-10994","description":"Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).","status":"published","published":"2019-08-05T18:41:18Z","modified":"2024-08-04T22:40:15.649Z","cwes":["CWE-125"],"updated_at":"2026-11-02T14:20:19.056416Z"}],"euvd":[{"id":"EUVD-2019-2708","description":"Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).","status":"published","published":"2019-08-05T18:41:18Z","modified":"2024-08-04T22:40:15Z","updated_at":"2026-11-03T02:40:50.22256Z"}],"ghsa":[{"id":"GHSA-p462-h7q3-m5gx","title":"Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds...","description":"Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).","status":"published","published":"2022-05-24T16:52:34Z","modified":"2024-04-11T21:13:52Z","cvss":[{"version":"3.0","score":3.3,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","level":"low"}],"cwes":["CWE-125"],"updated_at":"2026-11-02T14:57:08.55794Z"}],"nvd":[{"id":"CVE-2019-10994","description":"Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).","status":"published","published":"2019-08-05T19:15:11.193Z","modified":"2026-06-17T02:12:04.793Z","cvss":[{"version":"3.0","score":3.3,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","level":"low","assessor":"primary"},{"version":"2.0","score":4.3,"vector":"AV:N/AC:M/Au:N/C:P/I:N/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-125"],"updated_at":"2026-11-02T14:05:21.892729Z"}]}}