{"id":"CVE-2019-11603","aliases":["EUVD-2019-3273","GHSA-542x-659m-wm39"],"status":"published","title":"Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software","description":"A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.","severity":{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.0242,"percentile":0.84286,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-22"],"published":"2019-08-21T19:29:23Z","modified":"2026-06-17T02:13:15Z","products":[{"vendor":"bosch","product":"iot_gateway_software"},{"vendor":"bosch","product":"prosyst_mbs_sdk"}],"references":[{"url":"https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-11603"},{"url":"https://github.com/advisories/GHSA-542x-659m-wm39"}],"sources":{"cve":[{"id":"CVE-2019-11603","title":"Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software","description":"A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.","status":"published","published":"2019-08-21T19:29:23.032Z","modified":"2024-09-16T23:46:18.811Z","cvss":[{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"cna"}],"updated_at":"2026-11-02T14:20:26.416173Z"}],"euvd":[{"id":"EUVD-2019-3273","description":"A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.","status":"published","published":"2019-08-21T19:29:23Z","modified":"2024-09-16T23:46:18Z","cvss":[{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high"}],"updated_at":"2026-11-03T00:54:46.734285Z"}],"ghsa":[{"id":"GHSA-542x-659m-wm39","title":"A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway...","description":"A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.","status":"published","published":"2022-05-24T16:54:21Z","modified":"2024-04-04T01:44:31Z","cvss":[{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:56:01.740944Z"}],"nvd":[{"id":"CVE-2019-11603","description":"A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.","status":"published","published":"2019-08-21T20:15:12.57Z","modified":"2026-06-17T02:13:15.21Z","cvss":[{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"secondary"},{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"primary"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:05:23.725587Z"}]}}