{"id":"CVE-2019-13537","aliases":["EUVD-2019-4992","GHSA-hpw3-432w-cv6v"],"status":"published","title":"The IEC870IP driver for AVEVA�s Vijeo Citect and Citect SCADA and Schneider Electric�s Power...","description":"The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.","severity":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.01297,"percentile":0.70582,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-121","CWE-787"],"published":"2020-01-14T18:05:51Z","modified":"2026-06-17T02:16:56Z","products":[{"vendor":"aveva","product":"iec870ip_firmware"},{"vendor":"aveva","product":"vijeo citect and citect scada"}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-19-290-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-13537"},{"url":"https://github.com/advisories/GHSA-hpw3-432w-cv6v"}],"sources":{"cve":[{"id":"CVE-2019-13537","description":"The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.","status":"published","published":"2020-01-14T18:05:51Z","modified":"2024-08-04T23:57:39.424Z","cwes":["CWE-121"],"updated_at":"2026-11-02T14:20:24.357095Z"}],"euvd":[{"id":"EUVD-2019-4992","description":"The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.","status":"published","published":"2020-01-14T18:05:51Z","modified":"2024-08-04T23:57:39Z","updated_at":"2026-11-03T02:40:42.016311Z"}],"ghsa":[{"id":"GHSA-hpw3-432w-cv6v","title":"The IEC870IP driver for AVEVA�s Vijeo Citect and Citect SCADA and Schneider Electric�s Power...","description":"The IEC870IP driver for AVEVA�s Vijeo Citect and Citect SCADA and Schneider Electric�s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.","status":"published","published":"2022-05-24T22:28:42Z","modified":"2023-01-30T05:05:17Z","updated_at":"2026-11-02T14:47:14.398767Z"}],"nvd":[{"id":"CVE-2019-13537","description":"The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.","status":"published","published":"2020-01-14T19:15:12.907Z","modified":"2026-06-17T02:16:56.09Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:N/I:N/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:05:42.416368Z"}]}}