{"id":"CVE-2019-25718","aliases":["EUVD-2019-20154","GHSA-gv7p-xf8g-c233"],"status":"published","title":"Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass","description":"Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause the device to display incorrect or no information from the connected Delta Family patient monitor.","severity":{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.00118,"percentile":0.01709,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-451"],"published":"2026-06-01T21:41:34Z","modified":"2026-07-22T18:10:00Z","products":[{"vendor":"draeger","product":"infinity_explorer_c700_firmware"},{"vendor":"dräger","product":"infinity explorer c700"}],"references":[{"url":"https://static.draeger.com/security/download/2019-01-22-draeger-infinity-delta-vf10-1-security-advisory.pdf","tags":["vendor-advisory","Vendor Advisory"]},{"url":"https://www.vulncheck.com/advisories/dr-ger-infinity-explorer-c700-privilege-escalation-via-kiosk-mode-bypass","tags":["third-party-advisory","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-25718"},{"url":"https://static.draeger.com/security"},{"url":"https://github.com/advisories/GHSA-gv7p-xf8g-c233"}],"sources":{"cve":[{"id":"CVE-2019-25718","title":"Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass","description":"Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause the device to display incorrect or no information from the connected Delta Family patient monitor.","status":"published","published":"2026-06-01T21:41:34.625Z","modified":"2026-07-15T01:24:11.79Z","cvss":[{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna"},{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-451"],"updated_at":"2026-11-02T14:20:19.399352Z"}],"euvd":[{"id":"EUVD-2019-20154","description":"Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause the device to display incorrect or no information from the connected Delta Family patient monitor.","status":"published","published":"2026-06-01T21:41:34Z","modified":"2026-07-15T01:24:11Z","cvss":[{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high"}],"updated_at":"2026-11-02T18:19:54.771384Z"}],"ghsa":[{"id":"GHSA-gv7p-xf8g-c233","title":"Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers...","description":"Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause the device to display incorrect or no information from the connected Delta Family patient monitor.","status":"published","published":"2026-06-02T00:31:57Z","modified":"2026-06-04T00:31:27Z","cvss":[{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"},{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-451"],"updated_at":"2026-11-02T15:08:32.060893Z"}],"nvd":[{"id":"CVE-2019-25718","description":"Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause the device to display incorrect or no information from the connected Delta Family patient monitor.","status":"published","published":"2026-06-01T23:16:13.27Z","modified":"2026-07-22T18:10:00.117Z","cvss":[{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"},{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"}],"cwes":["CWE-451"],"updated_at":"2026-11-02T14:05:50.275357Z"}]}}