{"id":"CVE-2019-25720","aliases":["EUVD-2019-20161","GHSA-4wcc-pjv3-vvw7"],"status":"published","title":"Dräger SC Monitoring Devices DoS via Malformed Network Packet","description":"Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.","severity":{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-07","score":0.00199,"percentile":0.09847,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-1286"],"published":"2026-06-03T16:56:29Z","modified":"2026-07-22T19:10:00Z","products":[{"vendor":"dräger","product":"sc 6002xl"},{"vendor":"dräger","product":"sc 7000"},{"vendor":"dräger","product":"sc6802xl"},{"vendor":"dräger","product":"sc8000"},{"vendor":"dräger","product":"sc90000 xl"}],"references":[{"url":"https://static.draeger.com/security/download/2019-11-27-Draeger-SC7000-SC9000-security-advisory-update-v1-5.pdf","tags":["vendor-advisory"]},{"url":"https://www.vulncheck.com/advisories/dr-ger-sc-monitoring-devices-dos-via-malformed-network-packet","tags":["third-party-advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-25720"},{"url":"https://github.com/advisories/GHSA-4wcc-pjv3-vvw7"}],"sources":{"cve":[{"id":"CVE-2019-25720","title":"Dräger SC Monitoring Devices DoS via Malformed Network Packet","description":"Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.","status":"published","published":"2026-06-03T16:56:29.683Z","modified":"2026-06-03T17:44:47.456Z","cvss":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"cna"}],"cwes":["CWE-1286"],"updated_at":"2026-11-02T14:20:19.399352Z"}],"euvd":[{"id":"EUVD-2019-20161","description":"Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.","status":"published","published":"2026-06-03T16:56:29Z","modified":"2026-06-03T17:44:47Z","cvss":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","level":"high"}],"updated_at":"2026-11-02T18:20:53.780241Z"}],"ghsa":[{"id":"GHSA-4wcc-pjv3-vvw7","title":"Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a...","description":"Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.","status":"published","published":"2026-06-03T18:33:10Z","modified":"2026-06-03T18:33:19Z","cvss":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium"}],"cwes":["CWE-1286"],"updated_at":"2026-11-02T15:08:31.387226Z"}],"nvd":[{"id":"CVE-2019-25720","description":"Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.","status":"published","published":"2026-06-03T18:16:15.91Z","modified":"2026-07-22T19:10:00.12Z","cvss":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"secondary"}],"cwes":["CWE-1286"],"updated_at":"2026-11-02T14:05:50.275357Z"}]}}