{"id":"CVE-2019-6572","aliases":["EUVD-2019-16131","GHSA-q833-7p8r-rcqc"],"status":"published","title":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1...","description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.","severity":{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.02721,"percentile":0.8613,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-200","CWE-798"],"published":"2019-05-14T19:54:48Z","modified":"2026-06-17T02:39:17Z","products":[{"vendor":"siemens","product":"simatic wincc (tia portal)"},{"vendor":"siemens","product":"simatic wincc runtime advanced"},{"vendor":"siemens","product":"simatic wincc runtime professional"},{"vendor":"siemens","product":"simatic_hmi_comfort_outdoor_panels_firmware"},{"vendor":"siemens","product":"simatic_hmi_comfort_panels_firmware"},{"vendor":"siemens","product":"simatic_hmi_ktp_mobile_panels_ktp400f_firmware"},{"vendor":"siemens","product":"simatic_hmi_ktp_mobile_panels_ktp700_firmware"},{"vendor":"siemens","product":"simatic_hmi_ktp_mobile_panels_ktp700f_firmware"},{"vendor":"siemens","product":"simatic_hmi_ktp_mobile_panels_ktp900_firmware"},{"vendor":"siemens","product":"simatic_hmi_ktp_mobile_panels_ktp900f_firmware"},{"vendor":"siemens","product":"simatic_hmi_mp_firmware"},{"vendor":"siemens","product":"simatic_hmi_op_firmware"},{"vendor":"siemens","product":"simatic_hmi_tp_firmware"},{"vendor":"siemens","product":"simatic_wincc_\\(tia_portal\\)"},{"vendor":"siemens","product":"simatic_wincc_runtime"},{"vendor":"siemens ag","product":"simatic hmi classic devices (tp/mp/op/mp mobile panel)"},{"vendor":"siemens ag","product":"simatic hmi comfort outdoor panels 7\" \u0026 15\""},{"vendor":"siemens ag","product":"simatic hmi comfort panels 4\" - 22\""},{"vendor":"siemens ag","product":"simatic hmi ktp mobile panels ktp400f, ktp700, ktp700f, ktp900 und ktp900f"},{"vendor":"siemens ag","product":"simatic wincc (tia portal)"},{"vendor":"siemens ag","product":"simatic wincc runtime advanced"},{"vendor":"siemens ag","product":"simatic wincc runtime professional"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/108412","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://www.us-cert.gov/ics/advisories/ICSA-19-134-09","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-6572"},{"url":"https://github.com/advisories/GHSA-q833-7p8r-rcqc"}],"sources":{"cve":[{"id":"CVE-2019-6572","description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.","status":"published","published":"2019-05-14T19:54:48Z","modified":"2024-08-04T20:23:22.238Z","cwes":["CWE-200"],"updated_at":"2026-11-02T14:20:23.381621Z"}],"euvd":[{"id":"EUVD-2019-16131","description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.","status":"published","published":"2019-05-14T19:54:48Z","modified":"2024-08-04T20:23:22Z","updated_at":"2026-11-03T03:06:49.204502Z"}],"ghsa":[{"id":"GHSA-q833-7p8r-rcqc","title":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1...","description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.","status":"published","published":"2022-05-24T16:45:40Z","modified":"2023-01-28T05:05:05Z","updated_at":"2026-11-02T14:44:18.061425Z"}],"nvd":[{"id":"CVE-2019-6572","description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.","status":"published","published":"2019-05-14T20:29:04.2Z","modified":"2026-06-17T02:39:17.38Z","cvss":[{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","level":"critical","assessor":"primary"},{"version":"2.0","score":6.4,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-200","CWE-798"],"updated_at":"2026-11-02T14:05:13.880207Z"}]}}