{"id":"CVE-2019-6827","aliases":["EUVD-2019-16381","GHSA-w35v-55pp-hj6x"],"status":"published","title":"A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS),...","description":"A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.","severity":{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.01279,"percentile":0.70198,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-787"],"published":"2019-07-15T20:47:48Z","modified":"2026-06-17T02:39:45Z","products":[{"vendor":"schneider-electric","product":"interactive_graphical_scada_system"}],"references":[{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-02","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-671/","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-6827"},{"url":"https://github.com/advisories/GHSA-w35v-55pp-hj6x"}],"sources":{"cve":[{"id":"CVE-2019-6827","description":"A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.","status":"published","published":"2019-07-15T20:47:48Z","modified":"2024-08-04T20:31:04.402Z","cwes":["CWE-787"],"updated_at":"2026-11-02T14:20:23.381621Z"}],"euvd":[{"id":"EUVD-2019-16381","description":"A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.","status":"published","published":"2019-07-15T20:47:48Z","modified":"2024-08-04T20:31:04Z","updated_at":"2026-11-03T03:06:48.069977Z"}],"ghsa":[{"id":"GHSA-w35v-55pp-hj6x","title":"A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS),...","description":"A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.","status":"published","published":"2022-05-24T16:50:25Z","modified":"2023-01-28T05:05:29Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-787"],"updated_at":"2026-11-02T14:44:20.965343Z"}],"nvd":[{"id":"CVE-2019-6827","description":"A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.","status":"published","published":"2019-07-15T21:15:10.883Z","modified":"2026-06-17T02:39:45.057Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":6.8,"vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-787"],"updated_at":"2026-11-02T14:05:19.195714Z"}]}}