{"id":"CVE-2020-10615","aliases":["EUVD-2020-3063","GHSA-9w3w-gw8r-v3wj"],"status":"published","title":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122...","description":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.","severity":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-12","score":0.02568,"percentile":0.85369,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-121","CWE-787"],"published":"2020-04-15T18:28:01Z","modified":"2026-06-17T02:48:06Z","products":[{"vendor":"trianglemicroworks","product":"scada_data_gateway"}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-547/","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-10615"},{"url":"https://github.com/advisories/GHSA-9w3w-gw8r-v3wj"}],"sources":{"cve":[{"id":"CVE-2020-10615","description":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.","status":"published","published":"2020-04-15T18:28:01Z","modified":"2024-08-04T11:06:10.164Z","cwes":["CWE-121"],"updated_at":"2026-11-02T14:35:48.213211Z"}],"euvd":[{"id":"EUVD-2020-3063","description":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.","status":"published","published":"2020-04-15T18:28:01Z","modified":"2024-08-04T11:06:10Z","updated_at":"2026-11-03T03:07:49.909738Z"}],"ghsa":[{"id":"GHSA-9w3w-gw8r-v3wj","title":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122...","description":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.","status":"published","published":"2022-05-24T17:14:39Z","modified":"2023-01-29T05:02:14Z","updated_at":"2026-11-02T14:45:02.058324Z"}],"nvd":[{"id":"CVE-2020-10615","description":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.","status":"published","published":"2020-04-15T19:15:13.753Z","modified":"2026-06-17T02:48:06.25Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:N/I:N/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:05:59.125695Z"}]}}