{"id":"CVE-2020-11483","aliases":["EUVD-2020-3836","GHSA-vv58-j7f9-q5xc"],"status":"published","title":"NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC...","description":"NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-12","score":0.01381,"percentile":0.72527,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-798"],"published":"2020-10-29T03:35:30Z","modified":"2026-06-17T02:50:14Z","products":[{"vendor":"intel","product":"bmc_firmware"},{"vendor":"nvidia","product":"nvidia dgx servers"}],"references":[{"url":"https://nvidia.custhelp.com/app/answers/detail/a_id/5010","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-11483"},{"url":"https://github.com/advisories/GHSA-vv58-j7f9-q5xc"}],"sources":{"cve":[{"id":"CVE-2020-11483","description":"NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.","status":"published","published":"2020-10-29T03:35:30Z","modified":"2024-08-04T11:28:14.182Z","updated_at":"2026-11-02T14:35:57.352161Z"}],"euvd":[{"id":"EUVD-2020-3836","description":"NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.","status":"published","published":"2020-10-29T03:35:30Z","modified":"2024-08-04T11:28:14Z","updated_at":"2026-11-03T03:07:46.270701Z"}],"ghsa":[{"id":"GHSA-vv58-j7f9-q5xc","title":"NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC...","description":"NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.","status":"published","published":"2022-05-24T17:32:29Z","modified":"2023-01-29T05:04:18Z","cwes":["CWE-798"],"updated_at":"2026-11-02T14:45:31.23097Z"}],"nvd":[{"id":"CVE-2020-11483","description":"NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.","status":"published","published":"2020-10-29T04:15:10.593Z","modified":"2026-06-17T02:50:14.83Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","level":"high","assessor":"primary"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:06:21.80969Z"}]}}
