{"id":"CVE-2020-12005","aliases":["EUVD-2020-4321","GHSA-p9x7-h752-wp55"],"status":"published","title":"FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected...","description":"FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.","severity":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.01842,"percentile":0.79162,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-434"],"published":"2020-06-15T19:22:59Z","modified":"2026-06-17T02:51:14Z","products":[{"vendor":"rockwellautomation","product":"factorytalk_linx"},{"vendor":"rockwellautomation","product":"rslinx_classic"}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-163-02","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-12005"},{"url":"https://github.com/advisories/GHSA-p9x7-h752-wp55"}],"sources":{"cve":[{"id":"CVE-2020-12005","description":"FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.","status":"published","published":"2020-06-15T19:22:59Z","modified":"2024-08-04T11:48:57.603Z","cwes":["CWE-434"],"updated_at":"2026-11-02T14:35:52.925152Z"}],"euvd":[{"id":"EUVD-2020-4321","description":"FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.","status":"published","published":"2020-06-15T19:22:59Z","modified":"2024-08-04T11:48:57Z","updated_at":"2026-11-03T03:07:41.399649Z"}],"ghsa":[{"id":"GHSA-p9x7-h752-wp55","title":"FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected...","description":"FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.","status":"published","published":"2022-05-24T17:20:29Z","modified":"2023-01-29T05:03:01Z","updated_at":"2026-11-02T14:45:13.764942Z"}],"nvd":[{"id":"CVE-2020-12005","description":"FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.","status":"published","published":"2020-06-15T20:15:11.473Z","modified":"2026-06-17T02:51:14.337Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":7.8,"vector":"AV:N/AC:L/Au:N/C:N/I:N/A:C","level":"high","assessor":"primary"}],"cwes":["CWE-434"],"updated_at":"2026-11-02T14:06:07.249892Z"}]}}