{"id":"CVE-2020-12028","aliases":["EUVD-2020-4344","GHSA-524h-35w7-86xp"],"status":"published","title":"Rockwell Automation FactoryTalk View SE","description":"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.","severity":{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.53033,"percentile":0.98987,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":true,"fix_available":false},"cwes":["CWE-264","CWE-306"],"published":"2020-07-20T15:17:11Z","modified":"2026-06-17T02:51:16Z","exploits":[{"source":"metasploit","id":"exploit/windows/scada/rockwell_factorytalk_rce","title":"Rockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution","type":"exploit","platform":"Windows","date":"2020-06-22","verified":true,"url":"https://www.rapid7.com/db/modules/exploit/windows/scada/rockwell_factorytalk_rce"}],"products":[{"vendor":"rockwell automation","product":"factorytalk view se"},{"vendor":"rockwellautomation","product":"factorytalk_view"}],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]},{"url":"http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-12028"},{"url":"https://github.com/advisories/GHSA-524h-35w7-86xp"}],"sources":{"cve":[{"id":"CVE-2020-12028","title":"Rockwell Automation FactoryTalk View SE","description":"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.","status":"published","published":"2020-07-20T15:17:11.738Z","modified":"2024-09-16T23:26:08.043Z","cvss":[{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N","level":"high","assessor":"cna"}],"cwes":["CWE-264"],"updated_at":"2026-11-02T14:35:52.925152Z"}],"euvd":[{"id":"EUVD-2020-4344","description":"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.","status":"published","published":"2020-07-20T15:17:11Z","modified":"2024-09-16T23:26:08Z","cvss":[{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N","level":"high"}],"updated_at":"2026-11-03T00:54:50.852699Z"}],"ghsa":[{"id":"GHSA-524h-35w7-86xp","title":"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize...","description":"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.","status":"published","published":"2022-05-24T17:23:57Z","modified":"2023-01-29T05:03:34Z","cvss":[{"version":"3.1","score":8.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","level":"high"}],"cwes":["CWE-306"],"updated_at":"2026-11-02T14:45:20.937669Z"}],"nvd":[{"id":"CVE-2020-12028","description":"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.","status":"published","published":"2020-07-20T16:15:12.163Z","modified":"2026-06-17T02:51:16.967Z","cvss":[{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N","level":"high","assessor":"secondary"},{"version":"3.1","score":8.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","level":"high","assessor":"primary"},{"version":"2.0","score":5.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-264","CWE-306"],"updated_at":"2026-11-02T14:06:10.086163Z"}]}}