{"id":"CVE-2020-12029","aliases":["EUVD-2020-4345","GHSA-v98p-v8hm-3f7c"],"status":"published","title":"Rockwell Automation FactoryTalk View SE","description":"All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.","severity":{"version":"3.1","score":9,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.46968,"percentile":0.98846,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":true,"fix_available":false},"cwes":["CWE-20"],"published":"2020-07-20T14:56:42Z","modified":"2026-06-17T02:51:17Z","exploits":[{"source":"metasploit","id":"exploit/windows/scada/rockwell_factorytalk_rce","title":"Rockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution","type":"exploit","platform":"Windows","date":"2020-06-22","verified":true,"url":"https://www.rapid7.com/db/modules/exploit/windows/scada/rockwell_factorytalk_rce"}],"products":[{"vendor":"rockwell automation","product":"factorytalk view se"},{"vendor":"rockwellautomation","product":"factorytalk_view"}],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]},{"url":"http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory","VDB Entry"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-12029"},{"url":"https://github.com/advisories/GHSA-v98p-v8hm-3f7c"}],"sources":{"cve":[{"id":"CVE-2020-12029","title":"Rockwell Automation FactoryTalk View SE","description":"All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.","status":"published","published":"2020-07-20T14:56:42.195Z","modified":"2024-09-16T22:02:56.282Z","cvss":[{"version":"3.1","score":9,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N","level":"critical","assessor":"cna"}],"cwes":["CWE-20"],"updated_at":"2026-11-02T14:35:52.925152Z"}],"euvd":[{"id":"EUVD-2020-4345","description":"All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.","status":"published","published":"2020-07-20T14:56:42Z","modified":"2024-09-16T22:02:56Z","cvss":[{"version":"3.1","score":9,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N","level":"critical"}],"updated_at":"2026-11-03T00:55:06.207566Z"}],"ghsa":[{"id":"GHSA-v98p-v8hm-3f7c","title":"All versions of FactoryTalk View SE do not properly validate input of filenames within a project...","description":"All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.","status":"published","published":"2022-05-24T22:28:58Z","modified":"2023-01-30T05:06:13Z","cwes":["CWE-20"],"updated_at":"2026-11-02T14:47:26.771464Z"}],"nvd":[{"id":"CVE-2020-12029","description":"All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.","status":"published","published":"2020-07-20T15:15:11.477Z","modified":"2026-06-17T02:51:17.1Z","cvss":[{"version":"3.1","score":9,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N","level":"critical","assessor":"secondary"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":6.8,"vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-20"],"updated_at":"2026-11-02T14:06:10.086163Z"}]}}