{"id":"CVE-2020-16222","aliases":["EUVD-2020-8188","GHSA-82hx-cp56-ffj8"],"status":"published","title":"Philips Patient Monitoring Devices Improper Authentication","description":"In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and \nPerformanceBridge Focal Point Version A.01, when an actor claims to have\n a given identity, the software does not prove or insufficiently proves \nthe claim is correct.","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-10","score":0.00549,"percentile":0.46278,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-287"],"published":"2020-09-11T12:55:23Z","modified":"2026-06-17T02:57:53Z","products":[{"vendor":"philips","product":"patient information center ix (picix)"},{"vendor":"philips","product":"patient_information_center_ix"},{"vendor":"philips","product":"performancebridge focal point"},{"vendor":"philips","product":"performancebridge_focal_point"}],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://www.philips.com/productsecurity","tags":["x_transferred"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-16222"},{"url":"https://github.com/advisories/GHSA-82hx-cp56-ffj8"}],"sources":{"cve":[{"id":"CVE-2020-16222","title":"Philips Patient Monitoring Devices Improper Authentication","description":"In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and \nPerformanceBridge Focal Point Version A.01, when an actor claims to have\n a given identity, the software does not prove or insufficiently proves \nthe claim is correct.","status":"published","published":"2020-09-11T12:55:23Z","modified":"2024-08-04T13:37:54.092Z","cwes":["CWE-287"],"updated_at":"2026-11-02T14:35:59.116379Z"}],"euvd":[{"id":"EUVD-2020-8188","description":"In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and \nPerformanceBridge Focal Point Version A.01, when an actor claims to have\n a given identity, the software does not prove or insufficiently proves \nthe claim is correct.","status":"published","published":"2020-09-11T12:55:23Z","modified":"2024-08-04T13:37:54Z","updated_at":"2026-11-03T03:07:28.673063Z"}],"ghsa":[{"id":"GHSA-82hx-cp56-ffj8","title":"Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point...","description":"Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.","status":"published","published":"2022-05-24T17:28:05Z","modified":"2023-12-21T05:04:04Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-287"],"updated_at":"2026-11-02T14:55:15.236949Z"}],"nvd":[{"id":"CVE-2020-16222","description":"In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and \nPerformanceBridge Focal Point Version A.01, when an actor claims to have\n a given identity, the software does not prove or insufficiently proves \nthe claim is correct.","status":"published","published":"2020-09-11T13:15:11.3Z","modified":"2026-06-17T02:57:53.163Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":5.8,"vector":"AV:A/AC:L/Au:N/C:P/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-287"],"updated_at":"2026-11-02T14:06:14.981587Z"}]}}