{"id":"CVE-2020-16228","aliases":["EUVD-2020-8194","GHSA-g25m-mg72-9v2w"],"status":"published","title":"Philips Patient Monitoring Devices Improper Check for Certificate Revocation","description":"In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.","severity":{"version":"3.1","score":6.4,"vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-10","score":0.00368,"percentile":0.3098,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-299"],"published":"2020-09-11T12:58:13Z","modified":"2026-06-17T02:57:54Z","products":[{"vendor":"philips","product":"intellivue patient monitors"},{"vendor":"philips","product":"intellivue x3"},{"vendor":"philips","product":"intellivue_mp2-mp90_firmware"},{"vendor":"philips","product":"intellivue_mx100_firmware"},{"vendor":"philips","product":"intellivue_mx400_firmware"},{"vendor":"philips","product":"intellivue_mx550_firmware"},{"vendor":"philips","product":"intellivue_mx600_firmware"},{"vendor":"philips","product":"intellivue_mx700_firmware"},{"vendor":"philips","product":"intellivue_mx750_firmware"},{"vendor":"philips","product":"intellivue_mx800_firmware"},{"vendor":"philips","product":"intellivue_mx850_firmware"},{"vendor":"philips","product":"intellivue_x2_firmware"},{"vendor":"philips","product":"intellivue_x3_firmware"},{"vendor":"philips","product":"patient information center ix (picix)"},{"vendor":"philips","product":"patient_information_center_ix"},{"vendor":"philips","product":"performancebridge focal point"},{"vendor":"philips","product":"performancebridge_focal_point"}],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://www.philips.com/productsecurity","tags":["x_transferred"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-16228"},{"url":"https://github.com/advisories/GHSA-g25m-mg72-9v2w"}],"sources":{"cve":[{"id":"CVE-2020-16228","title":"Philips Patient Monitoring Devices Improper Check for Certificate Revocation","description":"In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.","status":"published","published":"2020-09-11T12:58:13Z","modified":"2024-08-04T13:37:54.179Z","cwes":["CWE-299"],"updated_at":"2026-11-02T14:35:59.116379Z"}],"euvd":[{"id":"EUVD-2020-8194","description":"In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.","status":"published","published":"2020-09-11T12:58:13Z","modified":"2024-08-04T13:37:54Z","updated_at":"2026-11-03T03:07:28.673063Z"}],"ghsa":[{"id":"GHSA-g25m-mg72-9v2w","title":"Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point...","description":"Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.","status":"published","published":"2022-05-24T17:28:06Z","modified":"2023-12-21T05:04:04Z","cvss":[{"version":"3.1","score":6.4,"vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L","level":"medium"}],"cwes":["CWE-299"],"updated_at":"2026-11-02T14:55:15.236949Z"}],"nvd":[{"id":"CVE-2020-16228","description":"In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.","status":"published","published":"2020-09-11T13:15:11.377Z","modified":"2026-06-17T02:57:54.003Z","cvss":[{"version":"3.1","score":6.4,"vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L","level":"medium","assessor":"primary"},{"version":"2.0","score":5.2,"vector":"AV:A/AC:L/Au:S/C:P/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-299"],"updated_at":"2026-11-02T14:06:14.981587Z"}]}}