{"id":"CVE-2020-28210","aliases":["EUVD-2020-20694","GHSA-qqr2-jjq7-8fwx"],"status":"published","title":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)...","description":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.","severity":{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-11","score":0.0081,"percentile":0.57342,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-79"],"published":"2020-11-19T21:01:31Z","modified":"2026-06-17T03:10:12Z","products":[{"vendor":"schneider-electric","product":"ecostruxure_building_operation"}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-315-04/","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-28210"},{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-315-04"},{"url":"https://github.com/advisories/GHSA-qqr2-jjq7-8fwx"}],"sources":{"cve":[{"id":"CVE-2020-28210","description":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.","status":"published","published":"2020-11-19T21:01:31Z","modified":"2026-05-28T20:05:17.49Z","cvss":[{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"adp"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:35:57.017407Z"}],"euvd":[{"id":"EUVD-2020-20694","description":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.","status":"published","published":"2020-11-19T21:01:31Z","modified":"2026-05-28T20:05:17Z","cvss":[{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium"}],"updated_at":"2026-11-02T18:21:01.680356Z"}],"ghsa":[{"id":"GHSA-qqr2-jjq7-8fwx","title":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)...","description":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.","status":"published","published":"2022-05-24T17:34:39Z","modified":"2026-05-28T21:33:04Z","cvss":[{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T15:08:22.24664Z"}],"nvd":[{"id":"CVE-2020-28210","description":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.","status":"published","published":"2020-11-19T21:15:12.277Z","modified":"2026-06-17T03:10:12.457Z","cvss":[{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"primary"},{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","level":"medium","assessor":"secondary"},{"version":"2.0","score":4.3,"vector":"AV:N/AC:M/Au:N/C:N/I:P/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:06:25.394006Z"}]}}