{"id":"CVE-2020-7573","aliases":["EUVD-2020-28698","GHSA-vxf6-7465-29gf"],"status":"published","title":"A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation...","description":"A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control.","severity":{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-11","score":0.01373,"percentile":0.72328,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-284"],"published":"2020-11-19T21:02:45Z","modified":"2026-06-17T03:25:02Z","products":[{"vendor":"schneider-electric","product":"webreports"}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-315-04/","tags":["x_refsource_MISC","x_transferred","Patch","Product","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-7573"},{"url":"https://github.com/advisories/GHSA-vxf6-7465-29gf"}],"sources":{"cve":[{"id":"CVE-2020-7573","description":"A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control.","status":"published","published":"2020-11-19T21:02:45Z","modified":"2024-08-04T09:33:19.573Z","cwes":["CWE-284"],"updated_at":"2026-11-02T14:35:58.787905Z"}],"euvd":[{"id":"EUVD-2020-28698","description":"A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control.","status":"published","published":"2020-11-19T21:02:45Z","modified":"2024-08-04T09:33:19Z","updated_at":"2026-11-03T03:07:59.603443Z"}],"ghsa":[{"id":"GHSA-vxf6-7465-29gf","title":"A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation...","description":"A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control.","status":"published","published":"2022-05-24T17:34:45Z","modified":"2023-02-01T05:03:17Z","cvss":[{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","level":"medium"}],"cwes":["CWE-284"],"updated_at":"2026-11-02T14:50:02.739665Z"}],"nvd":[{"id":"CVE-2020-7573","description":"A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control.","status":"published","published":"2020-11-19T22:15:15.52Z","modified":"2026-06-17T03:25:02.463Z","cvss":[{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","level":"medium","assessor":"primary"},{"version":"2.0","score":6.4,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-284"],"updated_at":"2026-11-02T14:06:25.394006Z"}]}}