{"id":"CVE-2021-22283","aliases":["EUVD-2021-9429","GHSA-wxvf-mm56-j2pq"],"status":"published","title":"MMS File Transfer Vulnerability impact on Distribution Automation products","description":"Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.","severity":{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00171,"percentile":0.06564,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-665"],"published":"2023-02-28T04:21:41Z","modified":"2026-06-17T03:36:56Z","products":[{"vendor":"abb","product":"evd4_firmware"},{"vendor":"abb","product":"merging unit- smu615"},{"vendor":"abb","product":"rec615_firmware"},{"vendor":"abb","product":"red615_iec_firmware"},{"vendor":"abb","product":"ref615_ansi_firmware"},{"vendor":"abb","product":"ref615_iec_firmware"},{"vendor":"abb","product":"ref615r_firmware"},{"vendor":"abb","product":"relion protection relays - 611 series"},{"vendor":"abb","product":"relion protection relays - 615 series cn 4.0 fp1"},{"vendor":"abb","product":"relion protection relays - 615 series iec 4.0 fp1"},{"vendor":"abb","product":"relion protection relays - 615 series iec 5.0"},{"vendor":"abb","product":"relion protection relays - 615 series iec 5.0 fp1"},{"vendor":"abb","product":"relion protection relays - 620 series iec/cn 2.0"},{"vendor":"abb","product":"relion protection relays - 620 series iec/cn 2.0 fp1"},{"vendor":"abb","product":"relion protection relays - rer615"},{"vendor":"abb","product":"relion protection relays - rex640 pcl1"},{"vendor":"abb","product":"relion protection relays - rex640 pcl2"},{"vendor":"abb","product":"relion protection relays - rex640 pcl3"},{"vendor":"abb","product":"relion_611_firmware"},{"vendor":"abb","product":"relion_615_ansi_firmware"},{"vendor":"abb","product":"relion_615_cn_firmware"},{"vendor":"abb","product":"relion_615_iec_firmware"},{"vendor":"abb","product":"relion_620_ansi_firmware"},{"vendor":"abb","product":"relion_620_cn_firmware"},{"vendor":"abb","product":"relion_620_iec_firmware"},{"vendor":"abb","product":"remote monitoring and control - rec615"},{"vendor":"abb","product":"rer615_firmware"},{"vendor":"abb","product":"rer620_firmware"},{"vendor":"abb","product":"rex640_pcl1_firmware"},{"vendor":"abb","product":"rex640_pcl2_firmware"},{"vendor":"abb","product":"rex640_pcl3_firmware"},{"vendor":"abb","product":"smu615_firmware"}],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch","tags":["x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22283"},{"url":"https://github.com/advisories/GHSA-wxvf-mm56-j2pq"}],"sources":{"cve":[{"id":"CVE-2021-22283","title":"MMS File Transfer Vulnerability impact on Distribution Automation products","description":"Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n","status":"published","published":"2023-02-28T04:21:41.776Z","modified":"2025-03-07T18:12:14.516Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"cna"}],"cwes":["CWE-665"],"updated_at":"2026-11-02T14:32:57.701381Z"}],"euvd":[{"id":"EUVD-2021-9429","description":"Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n","status":"published","published":"2023-02-28T04:21:41Z","modified":"2025-03-07T18:12:14Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium"}],"updated_at":"2026-11-02T20:53:10.22972Z"}],"ghsa":[{"id":"GHSA-wxvf-mm56-j2pq","title":"Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion...","description":"Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.","status":"published","published":"2023-02-28T06:30:26Z","modified":"2023-03-21T05:04:53Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","level":"medium"}],"cwes":["CWE-665"],"updated_at":"2026-11-02T14:54:22.471958Z"}],"nvd":[{"id":"CVE-2021-22283","description":"Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n","status":"published","published":"2023-02-28T05:15:12.26Z","modified":"2026-06-17T03:36:56.09Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"secondary"},{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"primary"}],"cwes":["CWE-665"],"updated_at":"2026-11-02T14:07:07.323379Z"}]}}