{"id":"CVE-2021-22701","aliases":["EUVD-2021-9836","GHSA-f3x2-w4cq-5v25"],"status":"published","title":"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650,...","description":"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.","severity":{"version":"3.1","score":4.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N","level":"medium","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-12","score":0.00334,"percentile":0.2715,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-352"],"published":"2021-02-19T15:15:16Z","modified":"2026-06-17T03:37:35Z","products":[{"vendor":"schneider-electric","product":"powerlogic_ion7400_firmware"},{"vendor":"schneider-electric","product":"powerlogic_ion7650_firmware"},{"vendor":"schneider-electric","product":"powerlogic_ion8300_firmware"},{"vendor":"schneider-electric","product":"powerlogic_ion8400_firmware"},{"vendor":"schneider-electric","product":"powerlogic_ion8500_firmware"},{"vendor":"schneider-electric","product":"powerlogic_ion8600_firmware"},{"vendor":"schneider-electric","product":"powerlogic_ion8650_firmware"},{"vendor":"schneider-electric","product":"powerlogic_ion8800_firmware"},{"vendor":"schneider-electric","product":"powerlogic_ion9000_firmware"},{"vendor":"schneider-electric","product":"powerlogic_pm8000_firmware"}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2021-040-01/","tags":["x_refsource_MISC","x_transferred","Mitigation","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22701"},{"url":"https://www.se.com/ww/en/download/document/SEVD-2021-040-01"},{"url":"https://github.com/advisories/GHSA-f3x2-w4cq-5v25"}],"sources":{"cve":[{"id":"CVE-2021-22701","description":"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.","status":"published","published":"2021-02-19T15:15:16Z","modified":"2026-05-29T13:30:09.092Z","cvss":[{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:H","level":"medium","assessor":"adp"}],"cwes":["CWE-352"],"updated_at":"2026-11-02T14:32:57.368269Z"}],"euvd":[{"id":"EUVD-2021-9836","description":"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.","status":"published","published":"2021-02-19T15:15:16Z","modified":"2026-05-29T13:30:09Z","cvss":[{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:H","level":"medium"}],"updated_at":"2026-11-02T18:21:01.215325Z"}],"ghsa":[{"id":"GHSA-f3x2-w4cq-5v25","title":"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650,...","description":"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.","status":"published","published":"2022-05-24T17:42:41Z","modified":"2026-05-29T15:30:23Z","cvss":[{"version":"3.1","score":4.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N","level":"medium"}],"cwes":["CWE-352"],"updated_at":"2026-11-02T15:08:22.826978Z"}],"nvd":[{"id":"CVE-2021-22701","description":"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.","status":"published","published":"2021-02-19T16:15:12.937Z","modified":"2026-06-17T03:37:35.413Z","cvss":[{"version":"3.1","score":4.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N","level":"medium","assessor":"primary"},{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:H","level":"medium","assessor":"secondary"},{"version":"2.0","score":3.5,"vector":"AV:N/AC:M/Au:S/C:N/I:P/A:N","level":"low","assessor":"primary"}],"cwes":["CWE-352"],"updated_at":"2026-11-02T14:06:50.031227Z"}]}}