{"id":"CVE-2021-36705","aliases":["EUVD-2021-23300","GHSA-6f6j-c55c-5gxx"],"status":"published","title":"In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible...","description":"In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.02621,"percentile":0.85575,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-77","CWE-78"],"published":"2021-08-06T13:19:17Z","modified":"2026-06-17T03:59:01Z","products":[{"vendor":"prolink","product":"prc2402m_firmware"}],"references":[{"url":"https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-36705"},{"url":"https://github.com/advisories/GHSA-6f6j-c55c-5gxx"}],"sources":{"cve":[{"id":"CVE-2021-36705","description":"In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system.","status":"published","published":"2021-08-06T13:19:17Z","modified":"2024-08-04T01:01:58.968Z","updated_at":"2026-11-02T14:33:06.32268Z"}],"euvd":[{"id":"EUVD-2021-23300","description":"In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system.","status":"published","published":"2021-08-06T13:19:17Z","modified":"2024-08-04T01:01:58Z","updated_at":"2026-11-03T03:24:29.329171Z"}],"ghsa":[{"id":"GHSA-6f6j-c55c-5gxx","title":"In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible...","description":"In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system.","status":"published","published":"2022-05-24T19:10:19Z","modified":"2023-01-27T05:03:04Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:42:09.625504Z"}],"nvd":[{"id":"CVE-2021-36705","description":"In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system.","status":"published","published":"2021-08-06T14:15:07.79Z","modified":"2026-06-17T03:59:01.523Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","level":"high","assessor":"primary"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:06:56.562207Z"}]}}
