{"id":"CVE-2021-36707","aliases":["EUVD-2021-23302","GHSA-f8hv-38c8-7mr9"],"status":"published","title":"In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary,...","description":"In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-10","score":0.02621,"percentile":0.85595,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-77"],"published":"2021-08-06T13:19:30Z","modified":"2026-06-17T03:59:01Z","products":[{"vendor":"prolink","product":"prc2402m_firmware"}],"references":[{"url":"https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-36707"},{"url":"https://github.com/advisories/GHSA-f8hv-38c8-7mr9"}],"sources":{"cve":[{"id":"CVE-2021-36707","description":"In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.","status":"published","published":"2021-08-06T13:19:30Z","modified":"2024-08-04T01:01:59.348Z","updated_at":"2026-11-02T14:33:06.32268Z"}],"euvd":[{"id":"EUVD-2021-23302","description":"In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.","status":"published","published":"2021-08-06T13:19:30Z","modified":"2024-08-04T01:01:59Z","updated_at":"2026-11-03T03:24:29.329171Z"}],"ghsa":[{"id":"GHSA-f8hv-38c8-7mr9","title":"In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary,...","description":"In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.","status":"published","published":"2022-05-24T19:10:18Z","modified":"2023-01-30T05:01:14Z","cwes":["CWE-77"],"updated_at":"2026-11-02T14:46:22.009402Z"}],"nvd":[{"id":"CVE-2021-36707","description":"In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.","status":"published","published":"2021-08-06T14:15:07.877Z","modified":"2026-06-17T03:59:01.74Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","level":"high","assessor":"primary"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:06:56.562207Z"}]}}