{"id":"CVE-2022-1404","aliases":["EUVD-2022-24720","GHSA-pv7j-rpwp-pp9x"],"status":"published","title":"Delta Electronics CNCSoft Out-of-bounds Read","description":"Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.","severity":{"version":"3.1","score":3.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","level":"low","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.00325,"percentile":0.25745,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-125"],"published":"2022-08-31T15:33:03Z","modified":"2026-06-17T04:22:23Z","products":[{"vendor":"delta electronics","product":"cncsoft"},{"vendor":"deltaww","product":"cncsoft"}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-132-01","tags":["x_refsource_MISC","x_transferred","Patch","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-1404"},{"url":"https://github.com/advisories/GHSA-pv7j-rpwp-pp9x"}],"sources":{"cve":[{"id":"CVE-2022-1404","title":"Delta Electronics CNCSoft Out-of-bounds Read","description":"Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.","status":"published","published":"2022-08-31T15:33:03.604Z","modified":"2025-04-16T16:11:36.584Z","cvss":[{"version":"3.1","score":3.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","level":"low","assessor":"cna"}],"cwes":["CWE-125"],"updated_at":"2026-11-02T14:34:38.263045Z"}],"euvd":[{"id":"EUVD-2022-24720","description":"Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.","status":"published","published":"2022-08-31T15:33:03Z","modified":"2025-04-16T16:11:36Z","cvss":[{"version":"3.1","score":3.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","level":"low"}],"updated_at":"2026-11-02T20:52:24.329168Z"}],"ghsa":[{"id":"GHSA-pv7j-rpwp-pp9x","title":"Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while...","description":"Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.","status":"published","published":"2022-09-01T00:00:23Z","modified":"2023-01-28T05:07:20Z","cvss":[{"version":"3.1","score":7.1,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H","level":"high"}],"cwes":["CWE-125"],"updated_at":"2026-11-02T14:44:31.117774Z"}],"nvd":[{"id":"CVE-2022-1404","description":"Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.","status":"published","published":"2022-08-31T16:15:09.64Z","modified":"2026-06-17T04:22:23.463Z","cvss":[{"version":"3.1","score":3.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","level":"low","assessor":"secondary"},{"version":"3.1","score":7.1,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H","level":"high","assessor":"primary"}],"cwes":["CWE-125"],"updated_at":"2026-11-02T14:07:26.802986Z"}]}}