{"id":"CVE-2022-22808","aliases":["EUVD-2022-27951","GHSA-p6hc-w7h4-q55x"],"status":"published","title":"A CWE-942: Permissive Cross-domain Policy with Untrusted Domains vulnerability exists that could...","description":"A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.00675,"percentile":0.52471,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-352","CWE-942"],"published":"2022-02-09T00:00:00Z","modified":"2026-06-17T04:29:04Z","products":[{"vendor":"schneider-electric","product":"hmibscea53d1edb_firmware"},{"vendor":"schneider-electric","product":"hmibscea53d1edl_firmware"},{"vendor":"schneider-electric","product":"hmibscea53d1edm_firmware"},{"vendor":"schneider-electric","product":"hmibscea53d1eds_firmware"},{"vendor":"schneider-electric","product":"hmibscea53d1eml_firmware"},{"vendor":"schneider-electric","product":"hmibscea53d1esm_firmware"},{"vendor":"schneider-electric","product":"hmibscea53d1ess_firmware"}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-02","tags":["x_transferred","Patch","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-22808"},{"url":"https://github.com/advisories/GHSA-p6hc-w7h4-q55x"}],"sources":{"cve":[{"id":"CVE-2022-22808","description":"A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","status":"published","published":"2022-02-09T00:00:00Z","modified":"2024-08-03T03:21:49.15Z","cwes":["CWE-352"],"updated_at":"2026-11-02T14:34:26.645563Z"}],"euvd":[{"id":"EUVD-2022-27951","description":"A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","status":"published","published":"2022-02-09T00:00:00Z","modified":"2024-08-03T03:21:49Z","updated_at":"2026-11-03T03:25:52.201883Z"}],"ghsa":[{"id":"GHSA-p6hc-w7h4-q55x","title":"A CWE-942: Permissive Cross-domain Policy with Untrusted Domains vulnerability exists that could...","description":"A CWE-942: Permissive Cross-domain Policy with Untrusted Domains vulnerability exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","status":"published","published":"2022-02-11T00:00:48Z","modified":"2023-01-31T05:05:24Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-352","CWE-942"],"updated_at":"2026-11-02T14:48:50.52088Z"}],"nvd":[{"id":"CVE-2022-22808","description":"A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","status":"published","published":"2022-02-09T23:15:19.243Z","modified":"2026-06-17T04:29:04.46Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":6.8,"vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","level":"medium","assessor":"primary"}],"cwes":["CWE-352"],"updated_at":"2026-11-02T14:07:12.155838Z"}]}}