{"id":"CVE-2022-24296","aliases":["EUVD-2022-29197","GHSA-9mwc-7fwx-973c"],"status":"published","title":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD...","description":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.","severity":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-08","score":0.01167,"percentile":0.67543,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-327"],"published":"2022-06-08T14:11:50Z","modified":"2026-06-17T04:31:34Z","products":[{"vendor":"mitsubishi","product":"ae-200a_firmware"},{"vendor":"mitsubishi","product":"ae-200e_firmware"},{"vendor":"mitsubishi","product":"ae-200j_firmware"},{"vendor":"mitsubishi","product":"ae-50a_firmware"},{"vendor":"mitsubishi","product":"ae-50e_firmware"},{"vendor":"mitsubishi","product":"ae-50j_firmware"},{"vendor":"mitsubishi","product":"ag-150a-a_firmware"},{"vendor":"mitsubishi","product":"ag-150a-j_firmware"},{"vendor":"mitsubishi","product":"eb-50gu-a_firmware"},{"vendor":"mitsubishi","product":"eb-50gu-j_firmware"},{"vendor":"mitsubishi","product":"ew-50a_firmware"},{"vendor":"mitsubishi","product":"ew-50e_firmware"},{"vendor":"mitsubishi","product":"ew-50j_firmware"},{"vendor":"mitsubishi","product":"g-150ad_firmware"},{"vendor":"mitsubishi","product":"gb-50a_firmware"},{"vendor":"mitsubishi","product":"gb-50ada-a_firmware"},{"vendor":"mitsubishi","product":"gb-50ada-j_firmware"},{"vendor":"mitsubishi","product":"te-200a_firmware"},{"vendor":"mitsubishi","product":"te-50a_firmware"},{"vendor":"mitsubishi","product":"tw-50a_firmware"}],"references":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-005_en.pdf","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]},{"url":"https://www.mee.co.jp/psirt/vulnerability/pdf/2022-001.pdf","tags":["x_refsource_MISC","x_transferred","Third Party Advisory"]},{"url":"https://jvn.jp/vu/JVNVU95298925/index.html","tags":["x_refsource_MISC","x_transferred","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-24296"},{"url":"https://github.com/advisories/GHSA-9mwc-7fwx-973c"}],"sources":{"cve":[{"id":"CVE-2022-24296","description":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.","status":"published","published":"2022-06-08T14:11:50Z","modified":"2024-08-03T04:07:02.409Z","updated_at":"2026-11-02T14:34:34.576287Z"}],"euvd":[{"id":"EUVD-2022-29197","description":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.","status":"published","published":"2022-06-08T14:11:50Z","modified":"2024-08-03T04:07:02Z","updated_at":"2026-11-03T03:25:49.559039Z"}],"ghsa":[{"id":"GHSA-9mwc-7fwx-973c","title":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD...","description":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.","status":"published","published":"2022-06-09T00:00:20Z","modified":"2023-01-27T05:03:46Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high"}],"cwes":["CWE-327"],"updated_at":"2026-11-02T14:42:19.36916Z"}],"nvd":[{"id":"CVE-2022-24296","description":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.","status":"published","published":"2022-06-08T15:15:07.927Z","modified":"2026-06-17T04:31:34.1Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"primary"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-327"],"updated_at":"2026-11-02T14:07:21.62951Z"}]}}