{"id":"CVE-2022-24317","aliases":["EUVD-2022-29215","GHSA-3f32-592h-7fx5"],"status":"published","title":"A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when...","description":"A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","severity":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.01206,"percentile":0.68541,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-862"],"published":"2022-02-09T22:05:03Z","modified":"2026-06-17T04:31:36Z","products":[{"vendor":"schneider-electric","product":"interactive_graphical_scada_system_data_server"}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-01","tags":["x_refsource_MISC","x_transferred","Patch","Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-324/","tags":["x_refsource_MISC","x_transferred","Patch","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-24317"},{"url":"https://github.com/advisories/GHSA-3f32-592h-7fx5"}],"sources":{"cve":[{"id":"CVE-2022-24317","description":"A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","status":"published","published":"2022-02-09T22:05:03Z","modified":"2024-08-03T04:07:02.387Z","cwes":["CWE-862"],"updated_at":"2026-11-02T14:34:34.940806Z"}],"euvd":[{"id":"EUVD-2022-29215","description":"A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","status":"published","published":"2022-02-09T22:05:03Z","modified":"2024-08-03T04:07:02Z","updated_at":"2026-11-03T03:25:49.559039Z"}],"ghsa":[{"id":"GHSA-3f32-592h-7fx5","title":"A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when...","description":"A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","status":"published","published":"2022-02-11T00:00:47Z","modified":"2023-02-03T05:05:58Z","cwes":["CWE-862"],"updated_at":"2026-11-02T14:53:49.274652Z"}],"nvd":[{"id":"CVE-2022-24317","description":"A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","status":"published","published":"2022-02-09T23:15:19.99Z","modified":"2026-06-17T04:31:36.557Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"primary"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-862"],"updated_at":"2026-11-02T14:07:12.155838Z"}]}}
