{"id":"CVE-2022-24388","aliases":["EUVD-2022-29280","GHSA-c7hc-987r-wh58"],"status":"published","title":"Authenticated Privileged Command Injection Vulnerability in Fidelis Network and Deception","description":"Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.01533,"percentile":0.75022,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-77","CWE-78"],"published":"2022-05-17T19:30:26Z","modified":"2026-06-17T04:31:44Z","products":[{"vendor":"fidelis cybersecurity","product":"fidelis deception"},{"vendor":"fidelis cybersecurity","product":"fidelis network"},{"vendor":"fidelissecurity","product":"deception"},{"vendor":"fidelissecurity","product":"network"}],"references":[{"url":"https://fidelissecurity.zendesk.com/hc/en-us/articles/6211730139411","tags":["x_refsource_CONFIRM","x_transferred","Permissions Required","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-24388"},{"url":"https://github.com/advisories/GHSA-c7hc-987r-wh58"}],"sources":{"cve":[{"id":"CVE-2022-24388","title":"Authenticated Privileged Command Injection Vulnerability in Fidelis Network and Deception","description":"Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.","status":"published","published":"2022-05-17T19:30:26.07Z","modified":"2024-09-16T20:17:22.513Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:34:34.576287Z"}],"euvd":[{"id":"EUVD-2022-29280","description":"Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.","status":"published","published":"2022-05-17T19:30:26Z","modified":"2024-09-16T20:17:22Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T00:55:15.468069Z"}],"ghsa":[{"id":"GHSA-c7hc-987r-wh58","title":"Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject...","description":"Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.","status":"published","published":"2022-05-18T00:00:28Z","modified":"2023-01-28T05:05:21Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:44:20.029387Z"}],"nvd":[{"id":"CVE-2022-24388","description":"Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.","status":"published","published":"2022-05-17T20:15:08.293Z","modified":"2026-06-17T04:31:44.903Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","level":"high","assessor":"primary"}],"cwes":["CWE-78","CWE-77"],"updated_at":"2026-11-02T14:07:20.264424Z"}]}}