{"id":"CVE-2022-25164","aliases":["EUVD-2022-29907","GHSA-m3pg-8xj4-p62w"],"status":"published","title":"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 all...","description":"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.","severity":{"version":"3.1","score":8.6,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.00904,"percentile":0.60102,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-312"],"published":"2022-11-24T23:21:25Z","modified":"2026-06-17T04:33:07Z","products":[{"vendor":"mitsubishi electric corporation","product":"gx works3"},{"vendor":"mitsubishi electric corporation","product":"mx opc ua module configurator-r"},{"vendor":"mitsubishielectric","product":"gx_works3"},{"vendor":"mitsubishielectric","product":"mx_opc_ua_module_configurator-r"}],"references":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf","tags":["vendor-advisory","x_transferred","Mitigation","Vendor Advisory"]},{"url":"https://jvn.jp/vu/JVNVU97244961/index.html","tags":["government-resource","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05","tags":["government-resource","x_transferred"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-25164"},{"url":"https://github.com/advisories/GHSA-m3pg-8xj4-p62w"}],"sources":{"cve":[{"id":"CVE-2022-25164","description":"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.","status":"published","published":"2022-11-24T23:21:25.536Z","modified":"2025-04-25T17:52:48.881Z","cvss":[{"version":"3.1","score":8.6,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","level":"high","assessor":"cna"}],"cwes":["CWE-312"],"updated_at":"2026-11-02T14:34:28.707644Z"}],"euvd":[{"id":"EUVD-2022-29907","description":"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.","status":"published","published":"2022-11-24T23:21:25Z","modified":"2025-04-25T17:52:48Z","cvss":[{"version":"3.1","score":8.6,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","level":"high"}],"updated_at":"2026-11-02T20:52:02.967137Z"}],"ghsa":[{"id":"GHSA-m3pg-8xj4-p62w","title":"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 all...","description":"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 all versions and Mitsubishi Electric MX OPC UA Module Configurator-R all versions allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthorized users can gain unauthorized access to the CPU module and the OPC UA server module.","status":"published","published":"2022-11-25T00:30:59Z","modified":"2023-05-31T09:30:17Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high"}],"cwes":["CWE-312"],"updated_at":"2026-11-02T14:54:37.773458Z"}],"nvd":[{"id":"CVE-2022-25164","description":"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.","status":"published","published":"2022-11-25T00:15:09.907Z","modified":"2026-06-17T04:33:07.91Z","cvss":[{"version":"3.1","score":8.6,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","level":"high","assessor":"secondary"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"primary"}],"cwes":["CWE-312"],"updated_at":"2026-11-02T14:07:32.827264Z"}]}}
