{"id":"CVE-2022-32536","aliases":["EUVD-2022-35604","GHSA-54wx-g7x6-gj3j"],"status":"published","title":"Privilege Escalation","description":"The user access rights validation in the web server of the Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 was insufficient. This would allow a non-administrator user to obtain administrator user access rights.","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.01073,"percentile":0.65148,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-269"],"published":"2022-06-22T13:55:56Z","modified":"2026-06-17T04:47:29Z","products":[{"vendor":"bosch","product":"pra-es8p2s"},{"vendor":"bosch","product":"pra-es8p2s_firmware"}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-247052-BT.html","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-32536"},{"url":"https://github.com/advisories/GHSA-54wx-g7x6-gj3j"}],"sources":{"cve":[{"id":"CVE-2022-32536","title":"Privilege Escalation","description":"The user access rights validation in the web server of the Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 was insufficient. This would allow a non-administrator user to obtain administrator user access rights.","status":"published","published":"2022-06-22T13:55:56Z","modified":"2024-08-03T07:46:43.564Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-269"],"updated_at":"2026-11-02T14:34:36.917505Z"}],"euvd":[{"id":"EUVD-2022-35604","description":"The user access rights validation in the web server of the Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 was insufficient. This would allow a non-administrator user to obtain administrator user access rights.","status":"published","published":"2022-06-22T13:55:56Z","modified":"2024-08-03T07:46:43Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T03:25:31.522014Z"}],"ghsa":[{"id":"GHSA-54wx-g7x6-gj3j","title":"The user access rights validation in the web server of the Bosch Ethernet switch PRA-ES8P2S with...","description":"The user access rights validation in the web server of the Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 was insufficient. This would allow a non-administrator user to obtain administrator user access rights.","status":"published","published":"2022-06-24T00:00:30Z","modified":"2023-01-27T05:05:18Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-269"],"updated_at":"2026-11-02T14:42:39.886669Z"}],"nvd":[{"id":"CVE-2022-32536","description":"The user access rights validation in the web server of the Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 was insufficient. This would allow a non-administrator user to obtain administrator user access rights.","status":"published","published":"2022-06-23T17:15:13.81Z","modified":"2026-06-17T04:47:29.807Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","level":"high","assessor":"primary"}],"cwes":["CWE-269"],"updated_at":"2026-11-02T14:07:22.613788Z"}]}}