{"id":"CVE-2022-33175","aliases":["EUVD-2022-36219","GHSA-x3x3-7q8c-m397"],"status":"published","title":"Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an...","description":"Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.01738,"percentile":0.77873,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-276","CWE-732"],"published":"2022-06-13T17:03:47Z","modified":"2026-06-17T04:48:32Z","products":[{"vendor":"powertekpdus","product":"basic_pdu_firmware"},{"vendor":"powertekpdus","product":"piml_pdu_firmware"},{"vendor":"powertekpdus","product":"pm_pdu_firmware"},{"vendor":"powertekpdus","product":"smart_pim_firmware"},{"vendor":"powertekpdus","product":"smart_pom_firmware"},{"vendor":"powertekpdus","product":"smart_poms_firmware"},{"vendor":"powertekpdus","product":"smart_pos_firmware"}],"references":[{"url":"https://gynvael.coldwind.pl/?lang=en\u0026id=748","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-33175"},{"url":"https://github.com/advisories/GHSA-x3x3-7q8c-m397"}],"sources":{"cve":[{"id":"CVE-2022-33175","description":"Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.","status":"published","published":"2022-06-13T17:03:47Z","modified":"2024-08-03T08:01:20.393Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N","level":"critical","assessor":"cna"}],"updated_at":"2026-11-02T14:34:40.621895Z"}],"euvd":[{"id":"EUVD-2022-36219","description":"Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.","status":"published","published":"2022-06-13T17:03:47Z","modified":"2024-08-03T08:01:20Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N","level":"critical"}],"updated_at":"2026-11-03T03:25:31.011886Z"}],"ghsa":[{"id":"GHSA-x3x3-7q8c-m397","title":"Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an...","description":"Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.","status":"published","published":"2022-06-14T00:00:28Z","modified":"2023-01-27T05:04:06Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-276"],"updated_at":"2026-11-02T14:42:23.611991Z"}],"nvd":[{"id":"CVE-2022-33175","description":"Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.","status":"published","published":"2022-06-13T18:15:10.283Z","modified":"2026-06-17T04:48:32.777Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","level":"high","assessor":"primary"}],"cwes":["CWE-732"],"updated_at":"2026-11-02T14:07:22.232533Z"}]}}