{"id":"CVE-2022-34438","aliases":["EUVD-2022-37393","GHSA-gj3h-47qp-ppc2"],"status":"published","title":"Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A...","description":"Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A local authenticated malicious user with high privileges could potentially exploit this vulnerability, leading to full system compromise. This impacts compliance mode clusters.","severity":{"version":"3.1","score":6.7,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.00182,"percentile":0.07885,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-269"],"published":"2022-10-21T18:05:28Z","modified":"2026-06-17T04:50:21Z","products":[{"vendor":"dell","product":"emc_powerscale_onefs"},{"vendor":"dell","product":"powerscale onefs"}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000204053/dsa-2022-245-dell-emc-powerscale-onefs-security-update-for-multiple-security-updates","tags":["x_transferred","Patch","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-34438"},{"url":"https://github.com/advisories/GHSA-gj3h-47qp-ppc2"}],"sources":{"cve":[{"id":"CVE-2022-34438","description":"Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A local authenticated malicious user with high privileges could potentially exploit this vulnerability, leading to full system compromise. This impacts compliance mode clusters.","status":"published","published":"2022-10-21T18:05:28.29Z","modified":"2025-05-07T15:39:17.442Z","cvss":[{"version":"3.1","score":6.7,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"medium","assessor":"cna"}],"cwes":["CWE-269"],"updated_at":"2026-11-02T14:34:42.028422Z"}],"euvd":[{"id":"EUVD-2022-37393","description":"Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A local authenticated malicious user with high privileges could potentially exploit this vulnerability, leading to full system compromise. This impacts compliance mode clusters.","status":"published","published":"2022-10-21T18:05:28Z","modified":"2025-05-07T15:39:17Z","cvss":[{"version":"3.1","score":6.7,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"medium"}],"updated_at":"2026-11-02T20:32:53.098709Z"}],"ghsa":[{"id":"GHSA-gj3h-47qp-ppc2","title":"Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A...","description":"Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A local authenticated malicious user with high privileges could potentially exploit this vulnerability, leading to full system compromise. This impacts compliance mode clusters.","status":"published","published":"2022-10-21T19:01:11Z","modified":"2023-01-29T05:03:10Z","cvss":[{"version":"3.1","score":6.7,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"medium"}],"cwes":["CWE-269"],"updated_at":"2026-11-02T14:45:15.626641Z"}],"nvd":[{"id":"CVE-2022-34438","description":"Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A local authenticated malicious user with high privileges could potentially exploit this vulnerability, leading to full system compromise. This impacts compliance mode clusters.","status":"published","published":"2022-10-21T18:15:09.97Z","modified":"2026-06-17T04:50:21.467Z","cvss":[{"version":"3.1","score":6.7,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"medium","assessor":"secondary"},{"version":"3.1","score":6.7,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"medium","assessor":"primary"}],"cwes":["CWE-269"],"updated_at":"2026-11-02T14:07:31.127985Z"}]}}