{"id":"CVE-2022-34456","aliases":["EUVD-2022-37411","GHSA-5chh-9f53-cmg6"],"status":"published","title":"Dell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An...","description":"Dell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.00868,"percentile":0.58994,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-94"],"published":"2023-01-18T05:11:42Z","modified":"2026-06-17T04:50:23Z","products":[{"vendor":"dell","product":"emc_metro_node"},{"vendor":"dell emc","product":"metro node"}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000204057/dsa-2022-267-dell-emc-metronode-vs5-security-update-for-multiple-third-party-component-vulnerabilities","tags":["vendor-advisory","x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-34456"},{"url":"https://github.com/advisories/GHSA-5chh-9f53-cmg6"}],"sources":{"cve":[{"id":"CVE-2022-34456","description":"\nDell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.\n\n\n\n\n\n","status":"published","published":"2023-01-18T05:11:42.211Z","modified":"2025-04-03T19:33:34.207Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T14:34:42.028422Z"}],"euvd":[{"id":"EUVD-2022-37411","description":"\nDell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.\n\n\n\n\n\n","status":"published","published":"2023-01-18T05:11:42Z","modified":"2025-04-03T19:33:34Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-02T20:52:42.939917Z"}],"ghsa":[{"id":"GHSA-5chh-9f53-cmg6","title":"Dell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An...","description":"Dell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.","status":"published","published":"2023-01-18T06:31:02Z","modified":"2023-01-25T21:30:20Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T14:41:42.686985Z"}],"nvd":[{"id":"CVE-2022-34456","description":"\nDell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.\n\n\n\n\n\n","status":"published","published":"2023-01-18T06:15:11.577Z","modified":"2026-06-17T04:50:23.387Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T14:07:35.157734Z"}]}}
