{"id":"CVE-2022-34753","aliases":["EUVD-2022-37701","GHSA-mx84-3frj-x7gc"],"status":"published","title":"A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command...","description":"A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.71447,"percentile":0.99418,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-78"],"published":"2022-07-13T21:10:25Z","modified":"2026-06-17T04:50:51Z","exploits":[{"source":"nuclei","id":"CVE-2022-34753","title":"SpaceLogic C-Bus Home Controller \u003c=1.31.460 - Remote Command Execution","type":"detection template","url":"https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2022/CVE-2022-34753.yaml"}],"products":[{"vendor":"schneider electric","product":"spacelogic c-bus home controller"},{"vendor":"schneider-electric","product":"spacelogic_c-bus_home_controller_firmware"}],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf","tags":["x_refsource_MISC","x_transferred","Patch","Vendor Advisory"]},{"url":"http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-34753"},{"url":"https://github.com/advisories/GHSA-mx84-3frj-x7gc"}],"sources":{"cve":[{"id":"CVE-2022-34753","description":"A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)","status":"published","published":"2022-07-13T21:10:25.007Z","modified":"2024-09-16T19:14:26.516Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:34:42.354707Z"}],"euvd":[{"id":"EUVD-2022-37701","description":"A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)","status":"published","published":"2022-07-13T21:10:25Z","modified":"2024-09-16T19:14:26Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T00:55:25.259735Z"}],"ghsa":[{"id":"GHSA-mx84-3frj-x7gc","title":"A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command...","description":"A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)","status":"published","published":"2022-07-14T00:00:16Z","modified":"2023-01-27T05:06:05Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:42:49.857991Z"}],"nvd":[{"id":"CVE-2022-34753","description":"A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)","status":"published","published":"2022-07-13T21:15:08.163Z","modified":"2026-06-17T04:50:51.877Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:07:23.322724Z"}]}}