{"id":"CVE-2022-34765","aliases":["EUVD-2022-37713","GHSA-mxgc-gq8g-45hm"],"status":"published","title":"A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of...","description":"A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)","severity":{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.00567,"percentile":0.47332,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-668","CWE-73"],"published":"2022-07-13T21:11:13Z","modified":"2026-06-17T04:50:53Z","products":[{"vendor":"schneider electric","product":"opc ua modicon communication module"},{"vendor":"schneider electric","product":"x80 advanced rtu communication module"},{"vendor":"schneider-electric","product":"opc_ua_module_for_m580_firmware"},{"vendor":"schneider-electric","product":"x80_advanced_rtu_module_firmware"}],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf","tags":["x_refsource_MISC","x_transferred","Patch","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-34765"},{"url":"https://github.com/advisories/GHSA-mxgc-gq8g-45hm"}],"sources":{"cve":[{"id":"CVE-2022-34765","description":"A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)","status":"published","published":"2022-07-13T21:11:13.251Z","modified":"2024-09-16T19:40:21.506Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H","level":"medium","assessor":"cna"}],"cwes":["CWE-73"],"updated_at":"2026-11-02T14:34:42.354707Z"}],"euvd":[{"id":"EUVD-2022-37713","description":"A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)","status":"published","published":"2022-07-13T21:11:13Z","modified":"2024-09-16T19:40:21Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H","level":"medium"}],"updated_at":"2026-11-03T00:55:20.992168Z"}],"ghsa":[{"id":"GHSA-mxgc-gq8g-45hm","title":"A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of...","description":"A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)","status":"published","published":"2022-07-14T00:00:15Z","modified":"2023-01-27T05:06:04Z","cvss":[{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","level":"medium"}],"cwes":["CWE-73","CWE-668"],"updated_at":"2026-11-02T14:42:49.857991Z"}],"nvd":[{"id":"CVE-2022-34765","description":"A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)","status":"published","published":"2022-07-13T21:15:08.8Z","modified":"2026-06-17T04:50:53.25Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H","level":"medium","assessor":"secondary"},{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-73","CWE-668"],"updated_at":"2026-11-02T14:07:23.322724Z"}]}}